The Use of an Audible Metronome Improves Chest Compression During Cardiopulmonary Resuscitation on a Pediatric Simulation Manikin
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 155
- 主要终点
- Metronome effect on compression rate and depth
研究概览
简要总结
The purpose of this study is to determine if the use of a metronome improves chest compression rate and depth during cardiopulmonary resuscitation (CPR) on a pediatric manikin.
详细描述
The study will be conducted in the simulation laboratory at Miami Children's Hospital. Chest compressions will be performed on a compression pediatric simulator. It will consist of two main groups randomly assigned to chest compressions without an audible metronome and chest compressions with audible metronomic tones that beep 100 times per minute for chest compressions. The metronome will be used to coach the correct rate. The same people will complete both arms of the study at one visit. Specifically, the participants will do 2 minutes of chest compressions followed by a 15-minute break then another 2 minutes of chest compressions (to avoid fatigue) with an acceptable range for rate 90-110 BPM and depth of 38-51mm. The subjects will be informed about the metronome, but will not be informed about the measured variables, such as rate and depth of chest compressions. However, the participants will be reminded at the beginning of their visit about the PALS card, i.e. appropriate rate and depth. The use of "talking people noise" from YouTube will be played in the background to fully model a cardiac arrest scenario (to see if participants ignore the metronome) and will be used during each group session. A noise dosimeter will be used to ensure this noise level is the same for each scenario. The manikin's airway will be secured with an endotracheal tube with continuous ventilations so chest compressions can be continued without interruption. Recommendations for chest compression rate and depth are per Pediatric Advanced Life Support (PALS) according to the 2010 American Heart Association (AHA) guidelines.
Data will be collected via the manikin which will wirelessly transmit the data (chest compression rate and depth) to a computer. The manikin has CPR sensing and recording technology software built in. This software records sternum movement depth and rate of chest compressions. Criteria for adequate CPR quality are defined as compression rate between 90-110 per minute and compression depth between 38-51mm.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 盲法
- Single (Participant)
入排标准
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •health professionals with a minimum of basic life support training according to the 2010 AHA guidelines capable of performing chest compressions.
排除标准
- 未提供
结局指标
主要结局
Metronome effect on compression rate and depth
时间窗: Adequacy of chest compressions (in terms of rate and depth) under each intervention (with and without metronome) was assessed during two minutes
The mean of the percentage of compressions that were within an adequate rate (90-110 per minute) and adequate depth (38-51mm) with and without the metronome.
次要结局
未报告次要终点