Estimation of End tidal carbon dioxide using the Novel 3D printed reusable Dual EtCO2 - O2 universal adapter for Hudson mask versus two commercially available EtCO2 monitoring systems in spontaneously breathing patients: A prospective comparative crossover study.
试验速览
- 阶段
- 不适用
- 状态
- 尚未招募
- 发起方
- 入组人数
- 60
- 试验地点
- 1
- 主要终点
- To validate our Novel 3D Printed Dual EtCO2 O2 Universal Adapter for Hudson mask by comparing it with two other commercially available EtCO2 monitoring systems and arterial PaCO2.
研究概览
简要总结
- End tidal carbon dioxide is the level of carbon dioxide that is released at the end of an exhaled breath. It is an indispensable tool of perioperative monitoring which has given valuable insight into the adequacy of ventilation and perfusion. So much so that the ASA has made it a part of the minimum monitoring standards for all patients under anaesthesia or sedation. Spontaneously breathing patients who require sedation are frequently given supplementary oxygen via a simple Hudson mask. As sedation causes respiratory depression leading to hypoxemia and hypercarbia capnographic monitoring becomes mandatory. However Hudson masks do not have the provision to monitor end tidal CO2. Towards this we have designed a simple reusable adapter for the Hudson mask which allows us to monitor End tidal CO2 without interrupting the supplemental oxygen flow thus enhancing safety while keeping costs low. Our study plans to validate our Novel 3D Printed Dual EtCO2 O2 Universal Adapter by comparing it with two other commercially available EtCO2 monitoring systems and arterial PaCO2.
研究设计
- 研究类型
- Interventional
- 分配方式
- Other
- 盲法
- Participant and Outcome Assessor Blinded
入排标准
- 年龄范围
- 18.00 Year(s) 至 50.00 Year(s)(—)
- 性别
- All
入选标准
- •Adult patients aged 18 to 50 years, ASA 1 and ASA 2 patients, posted for elective surgery under regional anaesthesia.
排除标准
- •Surgeries lasting for less than one hour, Patients who were not willing to take part in the study, Active upper respiratory tract infection, COPD, Chronic smokers, Bronchial asthma, Obstructive sleep apnea, Obesity, Hypotension, shock, hemodynamic instability, hypovolemia, sepsis, Hypothermia, Need for intubation, Intraoperative opioid usage.
结局指标
主要结局
To validate our Novel 3D Printed Dual EtCO2 O2 Universal Adapter for Hudson mask by comparing it with two other commercially available EtCO2 monitoring systems and arterial PaCO2.
时间窗: The EtCO2 (end tidal carbon dioxide) is recorded with the Novel adapter first at every 2 minute interval over 10 minutes. The mean value is calculated from the 5 recordings of EtCO2 obtained over 10 minutes. The same process is repeated using the two commercially available devices. Oxygen is supplemented at 5 litres per minute in all devices. Arterial PaCO2 is also measured. The time taken to complete the entire test on each patient is estimated to be 45 minutes.
次要结局
未报告次要终点
研究者
Dr Deepashri Marieta P J
Saveetha Medical College and Hospital, SIMATS, Chennai