跳至主要内容
临床试验/NCT07653178
NCT07653178进行中(未招募)不适用

Preoperative Bone Defect Volume Estimation Using the Hemielipsoid Formula for Allograft Planning in Musculoskeletal Tumor Surgery: A Prospective Validation Study Against Intraoperative Fluid Displacement Measurement

Sakarya University1 个研究点 分布在 1 个国家目标入组 40 人开始时间: 2026年6月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
进行中(未招募)
发起方
入组人数
40
试验地点
1

研究概览

简要总结

Bone defects following primary musculoskeletal tumor resection are frequently reconstructed using structural allografts. Allograft availability is limited, and intraoperative waste due to oversized graft selection remains a practical challenge in orthopedic oncology. Accurate preoperative estimation of the expected defect volume is therefore critical not only for surgical planning but also for minimizing unnecessary allograft use.

This prospective study aims to evaluate the accuracy of the preoperative hemielipsoid formula in estimating bone defect volume after primary musculoskeletal tumor resection, using intraoperative fluid displacement as the reference standard. A secondary aim is to determine whether preoperative CT-based hemielipsoid volume calculation can reliably guide allograft selection and reduce intraoperative graft waste.

Patients scheduled for primary musculoskeletal tumor resection with structural allograft reconstruction at Sakarya University Training and Research Hospital will be enrolled. Preoperative defect volume will be estimated using the hemielipsoid formula (V = 4/3 × π × a × b × c / 2) derived from preoperative CT measurements. Intraoperative defect volume will be measured by fluid displacement as the reference standard. Agreement between methods will be assessed by Bland-Altman analysis and intraclass correlation coefficient (ICC).

详细描述

**Background:** In orthopedic oncology, structural allograft reconstruction following primary musculoskeletal tumor resection requires precise preoperative planning. Currently, allograft selection at our institution relies on the surgeon's intraoperative visual estimation, with no standardized preoperative volumetric assessment protocol in place. This approach may result in allograft waste due to oversized graft selection, which is particularly problematic given the limited availability of allograft bank resources.

**Rationale:** The hemielipsoid formula (V = 4/3 × π × a × b × c / 2) offers a simple, reproducible method for estimating irregular bone defect volumes from standard cross-sectional imaging. If validated against an intraoperative reference standard, this formula could serve as a practical preoperative planning tool to guide allograft selection and minimize unnecessary graft use.

**Study Design:** This is a single-center prospective observational study conducted at Sakarya University Training and Research Hospital, Department of Orthopedics and Traumatology.

**Preoperative Assessment:** Defect volume will be estimated by the operating surgeon using the hemielipsoid formula applied to routine preoperative CT imaging. The three principal dimensions of the anticipated resection defect (length, width, and depth) will be measured on axial, coronal, and sagittal CT reconstructions, and volume will be calculated accordingly.

**Intraoperative Assessment:** Following tumor resection, the actual bone defect volume will be measured by direct cavity fluid displacement as the intraoperative reference standard. The resection cavity will be filled with a measured volume of saline to determine the true defect volume.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients diagnosed with a primary musculoskeletal tumor requiring surgical resection
  • Structural allograft reconstruction planned following resection
  • Routine preoperative CT imaging available for hemielipsoid measurements
  • Age ≥ 18 years
  • Written informed consent obtained

排除标准

  • Metastatic bone tumors
  • Pathological fracture at the resection site precluding accurate volume estimation
  • Prior surgery at the same anatomical site
  • Unavailability of adequate preoperative CT imaging
  • Reconstruction planned with implant or autograft only (no structural allograft)

研究组 & 干预措施

Hemielipsoid Volume Estimation Group

atients undergoing primary musculoskeletal tumor resection with structural allograft reconstruction. Preoperative bone defect volume is estimated using the hemielipsoid formula from CT imaging. Intraoperative defect volume is measured by saline cavity fill displacement as the reference standard.

干预措施: Hemielipsoid Formula-Based Preoperative and Intraoperative Bone Defect Volume Estimation (Procedure)

研究者

发起方
Sakarya University
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...