Investigation of the Effects of Target-Controlled Infusion (TCI) Anesthesia on Respiration, Recovery, and Electroencephalogram in Patients Undergoing Kyphoplasty in the Prone Position
试验速览
- 阶段
- 不适用
- 状态
- 尚未招募
- 发起方
- 入组人数
- 50
- 试验地点
- 1
- 主要终点
- . Number of Hypoxic Episodes
研究概览
简要总结
This single-center, prospective, observational study compares target-controlled infusion (TCI) versus manually administered total intravenous anesthesia (TIVA) for sedation in patients undergoing kyphoplasty in the prone position. The primary endpoints are the incidence of hypoxic episodes (SpO₂ < 90%) and apneic attacks. Secondary endpoints include anesthesia quality scores, integrated pulmonary index (IPI) values, total propofol consumption, time to eye opening, time to full orientation, Modified Aldrete Scores and Richmond Agitation-Sedation Scale (RASS) scores in the recovery unit, and patient and surgeon satisfaction.
详细描述
Kyphoplasty is a minimally invasive spinal procedure commonly performed for osteoporotic vertebral compression fractures. The procedure involves balloon elevation of the collapsed vertebral body followed by injection of polymethylmethacrylate (PMMA) bone cement for stabilization. The procedure is performed in the prone position and typically involves 1-2 vertebral levels.
Total intravenous anesthesia (TIVA), using combinations of propofol and remifentanil, is an alternative to inhalation anesthesia. TIVA can be administered manually or via target-controlled infusion (TCI) systems. TCI systems use pharmacokinetic models to achieve and maintain targeted plasma or effect-site concentrations. Studies in endoscopy settings have demonstrated that TCI-based sedation provides more stable sedation depth, fewer hemodynamic fluctuations, and faster recovery compared to manual administration.
Kyphoplasty procedures are typically performed in elderly patients with multiple comorbidities in the prone position under fluoroscopic guidance. The prone position, while mandatory for kyphoplasty, presents significant anesthesia management challenges: limited airway access increases the risk of respiratory depression during sedation, and chest compression impairs ventilation mechanics and may reduce alveolar ventilation. Therefore, meticulous respiratory monitoring during kyphoplasty is essential.
The Capnostream® device records four variables (SpO₂, respiratory rate, non-invasive EtCO₂, and heart rate) every 30 seconds via a nasal cannula and integrates them into a single unitless value called the Integrated Pulmonary Index (IPI), ranging from 1 to 10. An IPI of 4 or below requires intervention, while 8-10 represents the normal range. Additionally, bispectral index (BIS) monitoring enables objective tracking of anesthesia depth through EEG waveform analysis.
This study aims to compare manual TIVA versus TCI methods regarding sedation depth, respiratory stability, hemodynamic parameters, and recovery in patients undergoing kyphoplasty in the prone position. The findings are expected to contribute to determining the optimal anesthesia approach in this patient population.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •- Age 18 years and older
- •ASA physical status classification I-III
- •Scheduled for kyphoplasty under sedation in the prone position
- •Provision of written informed consent
排除标准
- •Known allergy to any of the study medications
- •ASA physical status classification IV or higher
- •Patients deemed unsuitable for sedation (high pulmonary risk, morbid obesity, diagnosed severe obstructive sleep apnea)
- •Refusal to participate or withdrawal of consent
- •Diagnosis of dementia or Alzheimer's disease
- •Communication difficulties precluding adequate assessment
结局指标
主要结局
. Number of Hypoxic Episodes
时间窗: from sedation initiation to end of procedure,Intraoperatively
Total number of episodes in which peripheral oxygen saturation drops below 90% during the procedure.(SpO₂ \< 90%)
次要结局
- Surgeon Satisfaction(end of the procedure.)
- Anesthesia Quality Score (0-32)(from sedation initiation to end of procedure, Intraoperatively.)
- Integrated Pulmonary Index (IPI) Values(Every 10 minutes intraoperatively, during sedation procedures)
- Total Propofol Consumption(Intraoperatively, from sedation initiation to end of procedure)
- Time to Eye Opening(From end of procedure to first eye opening, up to 10 minutes)
