Learning and Performance of Glidescope® Videolaryngoscope Intubation in Anesthesiologists Trained in Direct Laryngoscopy: a "in Vivo" Study
试验速览
- 阶段
- 不适用
- 发起方
- 入组人数
- 600
- 试验地点
- 1
- 主要终点
- number of attempts with Glidescope laryngoscopy necessary for beeing considered proficient
研究概览
简要总结
Glidescope laryngoscope was introduced as a novel tool for difficult intubation. Its learning curve was prooved on manikin but not in adult patients.
详细描述
Glidescope® Videolaryngoscope is an angulated rigid optical device introduced in clinical practice in 2004 to facilitate endotracheal intubation.
Since its introduction potential benefits of this instrument might lie with use in patients with clinical features indicating difficult laryngoscopy or it being used as a rescue method following failed direct laryngoscopy. In a few centers was proposed and used routinely.
The performance of Glidescope® was studied in easy and difficult scenarios, in vivo and on manikins and compared with the reference standard McIntosh direct laryngoscopy. In patients with predicted or simulated difficult intubation, despite glottis visualization was improved with Glidescope®, the introduction of the tube in trachea was difficult the same as with McIntosh laryngoscopy. Training of operators before to entertain the trials varied from 20 to 50 Glidescope successful intubations. In an observational study Aziz et al. demonstrated in the two Institutions involved that the GlideScope® was used more frequently at the Institution were the failure rate was significantly lower. At this , 51 providers performed mean 21.7 GlideScope® intubations while at the other 91 providers performed 9.9 intubations.
These data highlight the important issue of how many Glidescope® intubations a provider should complete to reach a definitive clinical competence in this practice. Until now there is only one study performed on mankin comparing Glidescope® with AirTraq® and McIntosh laryngoscopes in novices . The authors concluded that despite a steep learning curve after 5 intubation difficulties in instrumentation and longer times to intubate persisted with Glidescope® in comparison with the other two devices. Outcome measures were: duration of intubation attempt, modified Cormack grades, dental trauma and difficulty of use.
In vivo both timely insertion of laryngoscope blade and introduction of the tube, no need of help or of external laryngeal displacement should be included to ascertain expertise with this new technology in patients with different grades of difficulty predicted.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 16 Years 至 85 Years(Child, Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •any patient undergoing GA
排除标准
- •patients with predicted difficult intubation undergoing awake intubation
结局指标
主要结局
number of attempts with Glidescope laryngoscopy necessary for beeing considered proficient
时间窗: from induction of GA to successful intubation
from Glidescope blade insertion to succefull introduction of the tracheal tube and tube secured in the trachea with ETCO2 confirmation of tracheal ventilation
次要结局
- Features useful to define a Glidescope intubation successful(successfull intubation)