Balance Assessment of People With Lower Limb Impairment Practicing Amputee Football
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 66
- 试验地点
- 1
- 主要终点
- Center of pressure (CoP) path lenght was measured
研究概览
简要总结
Purpose of this study was to assess the balance level of highly qualified amputee football players in relation to their sports level, training experience, position on the pitch, as well as the type of amputation/dysfunction and disability experience.
详细描述
The participants were presented with the procedure of the study and informed that they could resign from their participation in the study at any stage. All participants were given the written informed consent form after the detailed written and oral explanation of the risk and benefits resulting from participation in this study Static balance was assessed using AMTI AccuSway stabilographic platform (ACS Model). The study participants performed the single 10 second left- or right-leg stance with eyes open (EO), and single 10 second left- or right-leg stance with eyes closed (EC) (depending on leg amputation). If the first attempt was not successful, study participants were able to do the second attempt. The tests were conducted on a match-free day, approximately 2 hours after a meal, in a sports outfit, in a specially designated room.
研究设计
- 研究类型
- Observational
- 观察模型
- Case Only
- 时间视角
- Cross Sectional
入排标准
- 年龄范围
- 16 Years 至 —(Child, Adult, Older Adult)
- 性别
- Male
- 接受健康志愿者
- 是
入选标准
- •participant of European Amputte Football Championschip
- •field player (leg amputation or leg dysfunction)
- •written consent form
排除标准
- •goalkeeper
- •tiredness
结局指标
主要结局
Center of pressure (CoP) path lenght was measured
时间窗: Baseline
CoP displacement analysis is used to assess postural sway, based on which the balance control function can be assessed
Surface area of stabilogram was mesured
时间窗: Baseline
Based on the analysis of the surface area of the stabilogram, the level of balance control can be assessed
Visual inspection indicator (VII) was measured
时间窗: Baseline
VII aggregates surface areas of stabilograms (cm2) with eyes open and closed. In theory, maximum value of the indicator may come to 100%. As a rule, it is positive, which means that the surface area of the stabilogram increases with eyes closed. The indicator is higher when the difference between the surface area of the stabilogram in the test with eyes closed and the surface area of the stabilogram in the test with eyes open is greater. Lower values of the VII may indicate a reduced role of visual control in maintaining balance or the lack of its compensation.