Skip to main content
Clinical Trials/NCT04707677
NCT04707677CompletedNot Applicable

Comparative Aesthetic Analysis Between Titanium and Ceramic Implants: A 12-month Randomized Clinical Trial.

University of Santiago de Compostela1 site in 1 country30 target enrollmentStarted: September 15, 2015Last updated:
Conditions
Interventions

Trial Snapshot

Phase
Not Applicable
Status
Completed
Enrollment
30
Locations
1
Primary Endpoint
The primary outcome was the Implant Crown Aesthetic Index (ICAI).

Study Overview

Brief Summary

Objective: The aim of this randomized clinical trial was to compare ceramic and titanium implants with respect to the esthetic and clinical parameters, and patient reported outcome measures (PROMs).

Material and methods: Thirty patients received thirty implants (8-12 mm in length, 3.3 mm diameter and a tissue level design) to replace the absence of a single tooth in the anterior maxilla. Patients were randomly allocated to receive a ceramic or a titanium implant. Esthetic and clinical parameters and PROMs were evaluated 18 months after surgery.

Detailed Description

The study was a double-blind randomized controlled clinical trial (RCT), with a parallel design, comparing ceramic (test group) and titanium (control group) implants, for the replacement of a single-tooth in the anterior maxilla.

All patients were randomized and assigned to each of the study groups through a computer-generated randomization.

Surgical and restorative procedures In the test group, a Tissue Level Ceramic monotype implant was placed (Straumann PURE Ceramic implants®; Institut Straumann, Basel, Switzerland) and in the control group a Tissue Level SLA Titanium implant (Straumann Standard Plus Narrow Neck CrossFit®; Institut Straumann, Basel, Switzerland). The length of the implants was 8, 10 and 12 mm.

The primary outcome was the Implant Crown Aesthetic Index (ICAI). It consists of nine sections: mesiodistal dimension of the crown, position of the incisal edge of the crown, labial convexity of the crown, color and translucency of the crown, crown surface, position of the gingival margin of the peri-implant mucosa, position of the interdental papilla, contour of the vestibular mucosa and color and surface of the vestibular mucosa. These sections were compared with the adjacent and contralateral tooth as a reference and assigned the following score: 0, excellent; 1 or 2 satisfactory; 3 or 4 moderate; 5 or more bad.

Study Design

Study Type
Interventional
Allocation
Randomized
Intervention Model
Parallel
Primary Purpose
Treatment
Masking
Double (Investigator, Outcomes Assessor)

Eligibility Criteria

Ages
18 Years to — (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
Yes

Inclusion Criteria

  • •Periodontal and systemically healthy patients > 18 years of age, with good plaque control (< 25%).
  • •Patients with a missing tooth in the anterior maxilla (from 13 to 23) with the presence of adjacent natural dentition mesially and distally (single gap). A minimum of 4 months of healing after tooth extraction was required before implant insertion.
  • •Presence of ≥ 2mm of keratinized tissue.
  • •Simultaneous bone regeneration was allowed during surgery.

Exclusion Criteria

  • •Intake any medication or presence of any systemic disease that could affect bone metabolism.
  • •Pregnancy, or lactating women.
  • •Active periodontal disease
  • •Smoking >10 cig/day

Arms & Interventions

CONTROL GROUP

Active Comparator

Implant surgery placement. Tissue Level SLA Titanium implant (Straumann Standard Plus Narrow Neck CrossFit®; Institut Straumann, Basel, Switzerland). The implant had a diameter of 3.3 mm and a polished neck of 1.8 mm. The length of the implants was 8, 10 and 12 mm and was chosen according to the patient's anatomy.

Intervention: Titanium and ceramic dental Implants (Device)

TEST GROUP

Experimental

Implant surgery placement. Tissue Level Ceramic monotype implant was placed (Straumann PURE Ceramic implants®; Institut Straumann, Basel, Switzerland). The implant had a diameter of 3.3 mm and a polished neck of 1.8 mm. The length of the implants was 8, 10 and 12 mm and was chosen according to the patient's anatomy.

Intervention: Titanium and ceramic dental Implants (Device)

Outcomes

Primary Outcomes

The primary outcome was the Implant Crown Aesthetic Index (ICAI).

Time Frame: 36 months

It consists of nine sections: (i) mesiodistal dimension of the crown, (ii) position of the incisal edge of the crown, (iii) labial convexity of the crown, (iv) color and translucency of the crown, (v) crown surface, (vi) position of the gingival margin of the peri-implant mucosa, (vii) position of the interdental papilla, (viii) contour of the vestibular mucosa and (ix) color and surface of the vestibular mucosa. These sections were compared with the adjacent and contralateral tooth as a reference and assigned the following score: 0, excellent; 1 or 2 satisfactory; 3 or 4 moderate; 5 or more bad (Meijer et al., 2005).

Secondary Outcomes

No secondary outcomes reported

Investigators

Sponsor Class
Other
Responsible Party
Principal Investigator
Principal Investigator

Juan Blanco Carrión

Doctorate in Dentistry

University of Santiago de Compostela

Study Sites (1)

Loading locations...

Similar Trials