跳至主要内容
临床试验/NCT02388386
NCT02388386已完成不适用

Pilot Study of Wireless Observed Therapy With an Ingestible Micro-Sensor Among Patients With Heart Failure and Left Ventricular Assist Devices

Scripps Translational Science Institute2 个研究点 分布在 1 个国家目标入组 10 人开始时间: 2015年2月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
10
试验地点
2
主要终点
System Performance - Positive Detection Accuracy

研究概览

简要总结

The investigators aim to develop a novel and wireless method for monitoring medication adherence among heart failure patients with left ventricular assist devices (LVADs). Proteus Digital™ has developed an ingestible and bio-absorbable micro-sensor as a strategy to monitor medication compliance. The edible sensor has at its core a silicon-based integrated circuit measuring 1.0 mm x 0.45 mm and is imbedded on a pill. Once ingested, this circuit is activated by gastric acid resulting in an electrochemical redox reaction and an electrical charge that is transmitted to a patch worn over the abdomen and wirelessly to a portable device such as a smart phone. This strategy of medication adherence differs from conventional adherence monitoring including pill counting and patient-recall by precisely tracking medication ingestion.

详细描述

The objectives are to assess the efficacy and safety of the Proteus Digital™ micro-sensor in an exploratory investigation among heart failure patients with LVADs. Medication adherence, specifically to anticoagulation is critically important in the post-implant period to maintain LVAD function and to decrease thromboembolic complications; however, commonly results in significant bleeding resulting in significant morbidity and mortality. In addition, the anticipated degree of anticoagulation is unpredictable after LVAD implantation due to factors related to changes in hepatic blood flow and endothelial dysfunction. Enrolling 10 patients will provide results into the function of micro-sensor and to provide a preliminary assessment of sensor-based activity, signal strength and signal duration in LVAD recipients. Participants will be enrolled during an in-patient hospitalization to assess the efficacy and safety of the device in a monitored setting.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

性别
All
接受健康志愿者

入选标准

  • Patients undergoing LVAD implantation for end-stage heart failure or admitted from the out-patient setting

排除标准

  • Unable to consistently consume oral intake
  • Hemodynamic instability defined as hypotension requiring intravenous vasoactive medications or arrhythmias requiring intravenous antiarrhythmics or oral antiarrhythmics for rhythm stabilization
  • Gastrointestinal bleeding requiring intravenous gastric acid secretion inhibitors

结局指标

主要结局

System Performance - Positive Detection Accuracy

时间窗: 30 minutes after ingestion

Primary outcome measure of system performance will be estimated by the positive detection accuracy, defined as the number of ingestible sensors detected divided by those ingested

次要结局

  • Number of Participants With Adverse Events as a Measure of Safety and Tolerability(From time of ingestion to 30 minutes after ingestion)

研究者

发起方
Scripps Translational Science Institute
申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验