Watershift - Pilot Study: Observing the Interindividual Effects and Mechanims of the Uptake, Storage and Excretion of Water
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 19
- 试验地点
- 1
- 主要终点
- Observing the absorption time, and the lay over time from deuterated water from the gast of deuterated water in the blood
研究概览
简要总结
The aim of this pilot was to study how body water behaves between the different internal water pools of the human body, what the role and influence of the interstitium is and what the effect is of body position on the distribution and allocation of BW between different body parts (trunk, legs, arms). To study this, 2 techniques that have not been used before in urological research were tested on their usefulness:
- The first technique is a recent BIA device, which distinguishes itself from earlier devices by measuring impedance at different electrical currencies in different body parts (arm/limb/trunk). This technique made it possible to observe the influence of body position on the distribution of BW in these body compartments. Rationale for this research question is mainly the link between NP and edema that was found in earlier research and the fact that body position seemed to have an impact on the size of edema. For this reason, it can be suggested that body position and thus edema will have an impact on whether or not NP occurs.
- The second technique uses deuterium as a biological marker. With this technique the distribution, storage, allocation and excretion of BW was examined among the urological most relevant water pools (blood, urine and interstitium).
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Basic Science
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 30 Years(Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Healthy individuals
- •Ages between 18 and 30
- •BMI between 18 and 24.9
排除标准
- •Intake of medications except of OAC
- •Patients with pacemaker or neurostimulator
结局指标
主要结局
Observing the absorption time, and the lay over time from deuterated water from the gast of deuterated water in the blood
时间窗: 3 hours
Aim of this overview is to assess how fast the deuterium oxide ingested in the human gastro-intestinal tractus, the colon and the blood pool. We want to know if this is 5min or even more 30 min and when the maximal dose of deuterium in the blood is reached.
Observing impedance changes linked with position switch
时间窗: 5 minutes
Decrease of impedance by 1 amplitude by changing positions grom standing to lying.
次要结局
未报告次要终点