跳至主要内容
临床试验/CTRI/2025/11/097015
CTRI/2025/11/097015尚未招募不适用

Design and Development of BHIMS a Medical non invasive device to measure translatory and rotatory movement of the scapula - A Multiphasic Study

未提供1 个研究点 分布在 1 个国家目标入组 46 人开始时间: 2025年11月17日最近更新:

试验速览

阶段
不适用
状态
尚未招募
入组人数
46
试验地点
1
主要终点
The newly developed device can measure translatory movements in mm and rotatory movements in angle . to check the validity on healthy individuals . the translatory movements and rotatory movements was compared with gold standard devices. Intra rater reliability was checked on the same individuals with a gap og 24 hours and inter rater reliability was checked with 2 qualified physiotherapists

研究概览

简要总结

The current research seeks to design and develop BHIMS, an innovative non-invasive medical device for the precise measurement of scapular translatory and rotatory movements. The multiphasic study encompasses the conceptualization, hardware-software integration, calibration, and validation of the device, succeeded by clinical testing on healthy individuals and targeted sports populations. BHIMS uses sensor-based technology to accurately and consistently record the parameters of scapular motion. The goal of the project is to show that the device is reliable, valid, and useful for physiotherapists and researchers who want to measure scapular kinematics in both static and dynamic situations.

研究设计

研究类型
Observational

入排标准

年龄范围
18.00 Year(s) 至 25.00 Year(s)(—)
性别
All

入选标准

  • 1.The ability to lift bilateral upper extremity upto 180 degree in frontal and saggital plane
  • No self reported medical conditions relating to the upper extremity or spine 3.Age 18-25 years both genders
  • Willingness to attend 2 testing sessions separated by atleast 24 hours.

排除标准

  • 1.Any Congenital defect of the scapula 2.Any history of shoulder girdle pain or pathology 3.Cervical pain or cervical radiculopathy pain with radiating to shoulder 4.Thoracic outlet syndrome 5.Surgery or trauma to thoracic spine , rib cage , shoulder girdle or cervical spine 6.Surgery or trauma to thoracic spine , rib cage , shoulder girdle or cervical spine 7.Leg length discrepancy.

结局指标

主要结局

The newly developed device can measure translatory movements in mm and rotatory movements in angle . to check the validity on healthy individuals . the translatory movements and rotatory movements was compared with gold standard devices. Intra rater reliability was checked on the same individuals with a gap og 24 hours and inter rater reliability was checked with 2 qualified physiotherapists

时间窗: validity checking 15 days and reliability 15 days

次要结局

  • To assess the bilateral translatory and rotatory movement of scapula among badminton players(1 week for assessment)

研究者

发起方
未提供
责任方
Principal Investigator
主要研究者

Dr Bindu Sarfare PT

School of Physiotherapy RK university

研究点 (1)

Loading locations...