跳至主要内容
临床试验/NCT01519973
NCT01519973终止不适用

Optimization of SPECT Cardiac Imaging Through Compensation for Attenuation, Resolution Loss and Scatter - The OSCARS

Ottawa Heart Institute Research Corporation1 个研究点 分布在 1 个国家目标入组 64 人开始时间: 2008年8月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
终止
入组人数
64
试验地点
1
主要终点
• Determine the accuracy of myocardial perfusion assessment using SPECT with AC/SC/RR compared to Rb-82 PET.

研究概览

简要总结

Single Photon Emission Computed Tomography (SPECT) is a 3D nuclear medicine imaging technique that is used extensively to study the heart and diagnose heart disease. There are three major limitations in SPECT imaging: attenuation or loss of signal, scattering of the signal in the patient tissues and resolution, where the signal gets blurrier the further the nuclear activity is away from the camera. New software, Evolution for CardiacTM, by GE Healthcare and new cameras with computed tomography (CT) decrease the time needed for images to be obtained while maintaining image quality. Evaluation is needed before they become standard of care.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Other
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Intermediate to high risk patients with coronary artery disease who are scheduled for routine SPECT or PET perfusion imaging

排除标准

  • •Pregnancy and breast feeding
  • •Severe narrowing (stenosis) of the aortic valve
  • •Severe heart failure

研究组 & 干预措施

Evaluation of technology in SPECT

Other

Evaluation of the accuracy of SPECT with new technologies for attenuation correction (AC), scatter correction (SC) and resolution recovery (RR) for assessment of myocardial perfusion using Rb-82 PET as the gold standard.

干预措施: SPECT/CT processed with Evolution for CardiacTM software (Radiation)

结局指标

主要结局

• Determine the accuracy of myocardial perfusion assessment using SPECT with AC/SC/RR compared to Rb-82 PET.

时间窗: 2 years

We are proposing a study to evaluate the accuracy of SPECT with the new technologies for attenuation correction (AC), scatter compensation (SC) and resolution recovery (RR) for the assessment of myocardial perfusion in patients with heart disease using Rb-82 perfusion PET as the gold standard for comparison.

次要结局

  • Determine the incremental benefit of AC/SC/RR compared to AC alone(2 years)
  • Determine if using a registered diagnostic CT (PET) increases the accuracy of CT-based AC over the lower-quality Hawkeye CT (SPECT).(2 years)
  • Determine if using a single CT scan acquired at stress for attenuation correction of both stress and rest SPECT decreases the accuracy over using CT scans acquired separately at rest and stress.(2 years)
  • Evaluate the effect on accuracy of using software with RR to reduce the acquisition time to half of the standard time.(2 years)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Terrence Ruddy

Terrence Ruddy, MD

Ottawa Heart Institute Research Corporation

研究点 (1)

Loading locations...

相似试验