Development and clinical application of next-generation navigation system in osteosynthesis and osteotomy
- Conditions
- Fracture, fracture malunion
- Registration Number
- JPRN-UMIN000040998
- Lead Sponsor
- Tokyo Medical University
- Brief Summary
1. Reproducibility evaluation of 3D preoperative planning based on 3D reference points. Reproducibility of the 3D preoperative plan for distal radius fracture osteosynthesis were an error of 1.9-2.2 mm. 2. Clinical significance of simple navigation in the osteosynthesis of distal radius fractures We evaluated the clinical significance of simple navigation for the osteosynthesis of distal radius fractures.The use of simple navigation reduced postoperative radius shortening.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- Recruiting
- Sex
- All
- Target Recruitment
- 500
Not provided
Patients with a pathological fractures, deformity of the same bone that may affect the performance of surgery, fractures, osteomyelitis, or patients who are unable to express their intentions due to consciousness disorder, etc.
Study & Design
- Study Type
- Interventional
- Study Design
- Not specified
- Primary Outcome Measures
Name Time Method Image evaluations before and after surgery
- Secondary Outcome Measures
Name Time Method Clinical evaluations before and after surgery