Efficacy of seventh-generation bonding agent (3M Single Bond Universal) vs fifth-generation bonding agent (Nano-Bond) in patients with dentin hypersensitivity: a randomized controlled clinical trial.
试验速览
- 阶段
- 1/2 期
- 状态
- 尚未招募
- 发起方
- 入组人数
- 45
- 试验地点
- 1
- 主要终点
- Discomfort Interval Scale (DIS) Schiff Cold Air Sensitivity Scale
研究概览
简要总结
Dentin hypersensitivity (DH) is a prevalent clinical condition characterized by short, sharp pain arising from exposed dentinal tubules in response to external stimuli such as cold, heat, or tactile contact. This study aims to evaluate the efficacy of the seventh-generation bonding agent (3M single bond universal) vs. the fifth-generation bonding agent (Nano-Bond) in patients with dentin hypersensitivity. Each group was labeled only by product identifiers—Group I, Group II, and Group III—with packaging made to look identical to maintain blinding. The participants were unaware of the treatment they would receive, and the clinical provider was similarly blinded. Results indicate that 3M Single Bond Universal shows better reduction in dentin hypersensitivity than Nanobond over a 3-month period
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 盲法
- None
入排标准
- 年龄范围
- 18.00 Year(s) 至 55.00 Year(s)(—)
- 性别
- All
入选标准
- •Systemically healthy patients Patients with class I gingival recession.
排除标准
- •Smokers Alcoholic patients patients who are systemically ill.
结局指标
主要结局
Discomfort Interval Scale (DIS) Schiff Cold Air Sensitivity Scale
时间窗: Baseline | Immediately after placement | 1 week | 1 month | 3 months
次要结局
未报告次要终点
研究者
Soumya
Lenora institute of dental sciences