Plate Fixation of Distal Femur Fractures: A Protocol for a Study of Two Plate Options
- Conditions
- Femoral Fractures
- Interventions
- Device: 95-degree Angled Blade PlateDevice: 4.5mm Condylar Locking Plate
- Registration Number
- NCT00644397
- Lead Sponsor
- MetroHealth Medical Center
- Brief Summary
Internal fixation of femur fractures improves alignment and provides stability to the bone and the surrounding soft tissues. This generally allows for early motion of the adjacent joints; thus maximizing overall function of the limb. Open reduction and internal fixation with plates and screws is the standard method that has been used in the treatment of distal femoral fractures. One common traditional method of internal fixation is the 95-degree angled blade plate. Recent advances in technology for distal femur fractures include the LCP™ Condylar Plate. This implant differs from the blade plate, because the LCP offers multiple points of fixed angle contact between the plate and screws in the distal femur. The introduction of plates with the option of locked screws has provided means to increase the rigidity of fixation in osteoporotic bone or in periarticular fractures with a small distal segment, and the LCP may be technically easier to apply than the blade plate. To the investigators' knowledge, there have been no published clinical or biomechanical studies specific to the LCP Condylar Plate, although the early results of LCP implants for other fractures are promising. The investigators believe that locked plating represents a valuable advancement in fracture treatment. However, the limitations of this new technology and the indications for its use have not been completely elucidated. Furthermore, the cost of the new technology is approximately seven times more than the traditional treatment. This is a randomized, prospective, multi-center study to compare the blade plate and the LCP in the distal femur. All patients 16 years of age or older, regardless of race or gender, with a supracondylar fracture of distal femur will be considered. Whether patients are treated with a blade plate or/and LCP, they will be receiving standard orthopedic care for their injury. Neither of these methods currently places a patient at increased surgical or post-surgical risk for problems with infection, nonunion, malunion, or other complications. Because of the study, early and late complication rates and functional outcomes after these treatments may be better defined, allowing for optimization of care of people with these injuries in the future. This should reduce not only direct and indirect costs to the individual, but also costs to society.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 80
- Closed or Gustilo 13,14 Type I, II or IIIA open fractures that can be treated with an angled blade plate or an LCP Condylar Plate (Orthopaedic Trauma Association fracture classification 33-A, 33- C1, 33- C2), (Tables 1 & Figure 3)
- 16 or more years of age and skeletally-mature, regardless of race or gender
- Pathologic fractures secondary to neoplasm
- Time elapsed since injury greater than 10 days before fixation
- Open fractures unable to undergo debridement and irrigation in the first 24 hours
- Inability or refusal to give consent
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Arm && Interventions
Group Intervention Description Blade Plate Group 95-degree Angled Blade Plate 95-degree Angled Blade Plate Locking Plate Group 4.5mm Condylar Locking Plate 4.5mm Condylar Locking Plate
- Primary Outcome Measures
Name Time Method
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
MetroHealth Medical Center
🇺🇸Cleveland, Ohio, United States