Treatment of Intracranial Wide-neck Aneurysms Using Stent-assisted Coil Embolization With the Codman Enterprise 2 Vascular Reconstruction Device.
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 10
- 试验地点
- 2
- 主要终点
- Device Effectiveness-Stent Migration
研究概览
简要总结
The primary objective of this study is to collect data regarding the effectiveness of using the Enterprise 2 Reconstruction Device in successfully embolizing intracranial aneurysms with wide neck configuration.
详细描述
The Codman Enterprise 2 Vascular Reconstruction Device is a self-expanding nitinol, compliant, closed-cell, recapturable design that can be deployed by a single operator. The Codman Enterprise 2 Vascular Reconstruction Device is packaged sterile as a single unit with an introducer sheath and a detachable push wire.
This device was designed to assist in the stent-assisted coil embolization of intracranial aneurysms, specifically those that have a wide neck that would not otherwise maintain the coil embolization material within the aneurysm because of the wide opening at the base of the aneurysm. The Codman Enterprise 2 Vascular Reconstruction Device is approved by the FDA as a Humanitarian Use Device (HUD) in cases of wide-necked saccular cerebral aneurysms.
The primary objective of this study is to collect data regarding the effectiveness of using the Enterprise 2 Reconstruction Device in successfully embolizing intracranial aneurysms with wide neck configuration. Secondly, to determine any safety or delivery problems that may occur, or any adverse patient events that may have previously been undocumented.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Adult patients (18 years old or older) with intracranial aneurysms with a wide neck (defined as > or = to 4mm, or with a dome to neck ratio of 2:1 or greater).
排除标准
- •Small-necked aneurysms, inappropriate for stenting.
- •Inability to tolerate anti-platelet medication.
结局指标
主要结局
Device Effectiveness-Stent Migration
时间窗: Patients will be followed for a minimum period of 2 years from the date of the procedure, with planned total duration of 4 years of the study, including follow-up time.
Prior Observation studies have noted in other stents, that over time, a stent may migrate from its original location, given the flow dynamics and potentially from stent under-sizing. This could potentially disrupt flow through the artery, or even uncover the aneurysm, openining, potentially allowing outflow of embolization coils.
Device Effectiveness- Stent Fore-shortening
时间窗: Patients will be followed for a minimum period of 2 years from the date of the procedure, with planned total duration of 4 years of the study, including follow-up time.
If a stent contracts slightly after placement, then it could shorten slightly, particularly if the stent is placed around a tortous corner. In this type of event, generally there is no significant impact to the patient, unless the stent were to shorten and uncover the opening of the aneurysm, potentially allowing embolization coils to come out of the aneurysm.
Device Effectiveness- In-stent stenosis
时间窗: Patients will be followed for a minimum period of 2 years from the date of the procedure, with planned total duration of 4 years of the study, including follow-up time.
In this known phenomenon with stents, it is possible that either through local inflammatory reaction or by hyper neointimalization, there can be a buildup of materila on the inner lumen of any stent that is placed.
次要结局
未报告次要终点