MedPath

Dual Mobility Cup Versus Unipolar Cup

Not Applicable
Not yet recruiting
Conditions
Dislocation, Hip
Interventions
Device: unipolar cup
Device: dual mobility cup
Registration Number
NCT04685239
Lead Sponsor
Northern Orthopaedic Division, Denmark
Brief Summary

The general purpose of this study is to examine whether the dual mobility cup (Novae® Serf) reduces the number of hip dislocations after total hip replacement, both early dislocation (≤1 year) and late dislocation (\>1 year) after primary THR compared with a conventional cup design (Trabecular MetalTM Modular Acetabular System).

Detailed Description

Surgery with THR for arthritis and other hip disorders has long been one of the most successful orthopedic surgical treatments. The majority of the patients gain pain relief and experience improved hip function. In 2017, a total of 10,691 THRs were implanted in Denmark (annual report 2018).

Hip dislocation is a known complication after THR. It is a painful condition which may have far-reaching consequences for the patient, who may experience both physical and mental discomfort. Ultimately, multiple hip dislocations may result in reoperation.

In the literature, the incidence of hip dislocation is reported at 2-6 %, and a more recent review reports a risk of 0.5-10 %.

In Denmark, recurrent hip dislocation is the cause of 21 % of the reoperations per year according to The Danish Hip Arthroplasty Register. According to the British National Joint Registry (NJR) and the Australian register (AOANJRR), hip dislocation is the cause of 15.5 % and 21 %, respectively, of the reoperations.

The best method to avoid reoperation due to instability is to choose the correct implant for the individual patient and thereby spare the patient of having to endure a painful complication and yet another procedure. There are multiple risk factors for instability after THR, and increased use of dual mobility cups (DMC) is already documented.

Recruitment & Eligibility

Status
NOT_YET_RECRUITING
Sex
All
Target Recruitment
1000
Inclusion Criteria
  • Patients with hip arthritis who are amenable to surgery with THR and age ≥ 65 years referred to the Department of Orthopedic Surgery at either Section Farsø, Frederikshavn Hospital or Aalborg University Hospital. Patients who are willing to participate in the trial and who give their written, informed consent after receiving oral and written information.
Exclusion Criteria
  • Patients who do not wish to participate.
  • Sequelae of Calvé-Legg-Perthes' disease, caput necrosis, epiphysiolysis.
  • Proximal femoral or acetabular fracture.
  • Hip dysplasia with subluxation Crowe types III and IV.
  • Earlier hip bone surgery (excluding arthroscopic surgery).
  • Elective bilateral surgery.
  • If the patient's bone morphology is unsuitable for a cemented Exeter® femoral stem.
  • Patients with no e-mail.

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
Unipolar cupunipolar cupPatients randomized to receive a conventional unipolar acetabular cup
dual mobility cupdual mobility cupPatients randomized to receive a double mobility acetabular cup
Primary Outcome Measures
NameTimeMethod
Early dislocation, Difference in dislocation within 1 year.1 year after surgery

The primary outcome is the difference in cumulative incidence proportion of dislocation between the 2 randomized groups within the first year after total hip replacement. The information will be collected from both the patient through questionnaires and from the Danish Hip Arthroplasty Register and the Danish National Patient Register.

Secondary Outcome Measures
NameTimeMethod
Difference in dislocation within 5 years5 years after surgery

The difference in cumulative incidence proportion of dislocation between the 2 randomized groups within 5 years after total hip replacement. The information will be collected from both the patient through questionnaires and from the Danish Hip Arthroplasty Register and the Danish National Patient Register.

Patient reported outcome measure: Oxford Hip Score (OHS)1, 5 and 10 years

Patients will be scored with OHS at baseline and at 1, 5 and 10 years. OHS is a patient-recorded outcome measure designed to assess the outcome of hip replacements. Its a score between 0-48 with 48 being the best.

Dislocation 10 year10 years after surgery

The difference in cumulative incidence proportion of dislocation between the 2 randomized groups within 10 years after total hip replacement. The information will be collected from both the patient through questionnaires and from the Danish Hip Arthroplasty Register and the Danish National Patient Register.

Patient reported outcome measure: European quality of life 5 dimensions (EQ-5D 5L)1, 5 and 10 years

Patients will be scored with EQ-5D 5L preoperatively and at 1,5 and 10 years. It consists of 5 dimensions ranging from 1-5, with 1 being the best in each dimension. It also consist of a visual analog scale ranging from 0-100, 100 being the best imaginable health, The EQ VAS describes the respondents current overall health. Data will be showed as changes in health over time showing responses at baseline and at follow up or as frequencies and proportions reported by dimension and level.

Patient reported outcome measures: The Copenhagen Hip and Groin Outcome Score (HAGOS)1, 5 and 10 years

HAGOS pain subscale will be used to report pain pre and postoperatively. The score in the pain subscale ranges from 0 (extreme hip/groin problems) -100 (no hip/groin problems).

Prosthesis survival.1, 5 and 10 year

Evaluated by the cumulative incidence of THR's reoperated within 1, 5 and 10 years after total hip replacement. The information will be collected from both the patient through questionnaires and from the Danish Hip Arthroplasty Register and the Danish National Patient Register.

Trial Locations

Locations (1)

Aalborg University Hospital

🇩🇰

Aalborg, Northen Denmark, Denmark

© Copyright 2025. All Rights Reserved by MedPath