A Prospective, Single-Arm Multi-Center Study of the ENSEAL® X1 Curved Jaw Tissue Sealer and Generator G11 in Thoracic, Urologic, and Ear, Nose, and Throat (ENT) Procedures
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 94
- 试验地点
- 7
- 主要终点
- Number of Vessels With Less Than or Equal to (<=) Grade 3 Hemostasis Based on Hemostasis Grading Scale
研究概览
简要总结
The purpose of this study is to demonstrate the acceptable performance and safety of the ENSEAL X1 curved jaw tissue sealer and Ethicon endo-surgery generator G11 (GEN11) devices when used per the instructions for use (IFU).
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Primary laparoscopic or open procedure (thoracic, urologic or ear, nose, and throat [ENT]) where at least one vessel is planned to be transected by the ENSEAL X1 curved jaw tissue sealer (ENSEAL X1) device per the Instructions for use (IFU)
- •Willingness to give consent and comply with all study-related evaluations and treatment schedule
- •At least 18 years of age
排除标准
- •Physical or psychological condition which would impair study participation
- •Enrollment in a concurrent interventional clinical study that could impact the study endpoints
结局指标
主要结局
Number of Vessels With Less Than or Equal to (<=) Grade 3 Hemostasis Based on Hemostasis Grading Scale
时间窗: On the day of transection (Day 0)
A 4-point grading scale was used to assess hemostasis in blood vessels. Grade 1: no bleeding at transection site; Grade 2: minor bleeding at transection site, no intervention needed; Grade 3: minor bleeding at transection site, mild intervention needed, use of compression, monopolar device and/or touch-ups with ENSEAL X1; or Grade 4: significant bleeding (example, pulsatile blood flow, venous pooling) requiring intervention such as extensive coagulation or use of additional hemostatic measures (example, hemoclips, staples, sutures, fibrin sealants, other advanced energy products). Here, the number of vessels that achieved \<=Grade 3 hemostasis was reported.
Number of Participants With at Least One Device-related Adverse Events (AEs)
时间窗: Baseline up to 6 weeks
Device-related AEs were those having a relationship of possibly, probably, or causally. 1. Possible-The relationship with use of device was weak but cannot be ruled out completely. Alternative causes were also possible. Cases where relatedness cannot be assessed, or no information had been obtained were also classified as possible. 2. Probable -The relationship with use of device seemed relevant and/or event cannot reasonably be explained by another cause, but additional information may be obtained; 3. Causal relationship-The event was associated with device or with procedures beyond reasonable doubt with event occurred such as, a known side effect; temporal relationship; involves a body-site or organ that device was applied or had an effect on; followed a known response pattern; impact on event when discontinued and reintroduced; Others; Harms due to error in use.
次要结局
- Number of Participants With Adhesion Removal or Division Using ENSEAL X1 Device as Assessed by Surgeon Satisfaction Scale Score(On the day of transection (Day 0))
- Number of Participants With Tissue Grasping Using ENSEAL X1 Device as Assessed by Surgeon Satisfaction Scale Score(On the day of transection (Day 0))
- Percentage of Grade 4 Vessel Transections Requiring Hemostasis Measures Such as Sutures and Hemoclips(On the day of transection (Day 0))
- Number of Participants With Tissue Cutting Using ENSEAL X1 Device as Assessed by Surgeon Satisfaction Scale Score(On the day of transection (Day 0))
- Number of Participants With Tissue Dissection Using ENSEAL X1 Device as Assessed by Surgeon Satisfaction Scale Score(On the day of transection (Day 0))
- Number of Participants With Lymphatics Bundles Division Using ENSEAL X1 Device as Assessed by Surgeon Satisfaction Scale Score(On the day of transection (Day 0))
- Number of Participants With Tissue Bundles Division Using ENSEAL X1 Device as Assessed by Surgeon Satisfaction Scale Score(On the day of transection (Day 0))
- Number of Vessels With Hemostasis (Grade 1 to 4) Based on Grading Scale(On the day of transection (Day 0))