A Multicenter Study Evaluating the Effectiveness of Endo.Angel in Improving the Quality of Colonoscopy
- Conditions
- Adenoma Detection Rate
- Interventions
- Diagnostic Test: colonoscopy without assistance of Endo.AngelDiagnostic Test: colonoscopy with assistance of Endo.Angel
- Registration Number
- NCT04102631
- Lead Sponsor
- Renmin Hospital of Wuhan University
- Brief Summary
Colonoscopy is a key technique in the detection and diagnosis of lower gastrointestinal diseases. High quality endoscopy results in better disease outcomes. However, the operant level of different endoscopists is significantly different.This study aims to construct a real-time quality monitoring system based on computer vision, named Endo.Angel, which is used to monitor the velocity of insertion of the endoscope, record the time of insertion and withdrawal of the endoscope, and remind endoscopists of the blind areas caused by intestinal segment slipping.
- Detailed Description
This study aims to construct a real-time quality monitoring system based on computer vision, named Endo.Angel, which is used to monitor the velocity of insertion of the endoscope, record the time of insertion and withdrawal of the endoscope, and remind endoscopists of the blind areas caused by intestinal segment slipping.Criteria for inclusion and exclusion are determined prior to endoscopic examination. Candidates who meet all inclusion criteria as well as do not meet all exclusion criteria are bring into the study. Participants randomized before the examination, they are divided into the exposed group assisted by Endo.Angel or the non-exposed group without Endo.Angel. Followup are conducted after the examination.Study will be finished when all followup is done,and the examination result collected from participants will send to an independent review data analysis group.
Recruitment & Eligibility
- Status
- UNKNOWN
- Sex
- All
- Target Recruitment
- 1076
Not provided
Not provided
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description non-exposed group colonoscopy without assistance of Endo.Angel patients will receive colonoscopy without assistance of Endo.Angel exposed group colonoscopy with assistance of Endo.Angel patients will receive colonoscopy with assistance of Endo.Angel
- Primary Outcome Measures
Name Time Method Adenoma detection rate 3 months The numerator is the number of cases of adenoma detected by colonoscopy, and the denominator is the total number of cases of patients undergoing colonoscopy.
- Secondary Outcome Measures
Name Time Method The mean number of adenomas per procedure 3 months The numerator is the total number of adenomas detected by colonoscopy, and the denominator is the total number of patients undergoing colonoscopy.
Polyp Detection Rate 3 months The numerator is the number of patients with polyps detected by colonoscopy, and the denominator is the total number of patients receiving colonoscopy.
Detection rate of large, small and minimal polyps 3 months The numerator was the number of patients with large (≥10 mm), small (4-9 mm), and minimal(≤5 mm) polyps detected by colonoscopy, and the denominator was the total number of patients receiving colonoscopy
The rate of reaching the ileocecal region 3 months The numerator is the number of cases of colonic examination reaching the ileocecal region, and the denominator is the total number of colonoscopy cases.
The mean number of polyps per procedure 3 months The numerator is the total number of polyps detected by colonoscopy, and the denominator is the total number of patients undergoing colonoscopy.
The mean number of large, small and minimal polyps per procedure 3 months The numerator was the number of large (≥10 mm), small (4-9 mm), and minimal (≤5 mm) polyps detected by colonoscopy, and the denominator was the total number of patients receiving colonoscopy.
The mean number of large, small and minimal adenomas per procedure 3 months The numerator was the number of large (≥10 mm), small (4-9 mm), and minimal (≤5 mm) adenomas detected by colonoscopy, and the denominator was the total number of patients receiving colonoscopy.
Time of colonoscopic withdrawal 3 months the duration of colonoscopic withdrawal(not include the time of biopsy or treatment).
Time of colonoscopic insertion 3 months The time of colonoscopy from the rectum to the ileocecal area.
The mean number of adenomas in different sites per procedure 3 months The numerator is the total number of adenomas detected in the rectum, sigmoid colon, descending colon, transverse colon, ascending colon and ileocecal region during colonoscopy, and the denominator is the total number of patients undergoing colonoscopy.
Detection rate of large, small and minimal adenomas 3 months The numerator was the number of patients with large (≥10 mm), small (4-9 mm), and minimal(≤5 mm) adenomas detected by colonoscopy, and the denominator was the total number of patients receiving colonoscopy
Detection rate of adenoma in different sites 3 months The numerator is the number of cases of adenoma detected in the rectum, sigmoid colon, descending colon, transverse colon, ascending colon and ileocecal region during colonoscopy, and the denominator is the total number of patients undergoing colonoscopy.
Trial Locations
- Locations (1)
Renmin Hospital of Wuhan University
🇨🇳Wuhan, Hubei, China