CeraFlex PFO Closure System Post-Market Clinical Follow-up Study: A Multi-center, Prospective, Observational, Post-market Study
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 入组人数
- 180
- 试验地点
- 25
- 主要终点
- Procedural success rate
研究概览
简要总结
The purpose of this study is to compile real-world data on patient outcomes and evaluate the procedural success and performance of the CeraFlex™ PFO Closure System.
详细描述
This is a multicenter, prospective, observational, single-arm, open-label, post-market Study. The study device is the Lifetech CeraFlex PFO closure system, which is composed of a) CeraFlex PFO Occluder, and b) SteerEase Introducer. The PFO Closure System is indicated for the non-surgical closure of Patent Foramen Ovale (PFO), and the study objective is to collect real-world data on patient outcomes and evaluate the procedural success and performance of the CeraFlex PFO Closure System.
The estimated enrollment period is approximately 18 months, and each subject will followed 24 months post-procedure. The assessment schedule at discharge, 1-3 months follow-up, 6 months follow-up, 12 months follow-up, and 24 months follow-up.
Electronic Date Capture (EDC) System will be used for this Study.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 85 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patient with indication(s) for PFO Occluder Closure in the Instruction For Use (IFU):
- •Confirmed PFO by medical examinations;
- •Associated with recurrent migraine/headache or TIA or cryptogenic stroke.
- •Patient characteristics consistent with the corresponding IFU & Device Size Selection:
- •Measure the distance from the defect to the aorta root;
- •Measure the distance from the defect to the superior vena cava (SVC) rim; select a device with the radius of the right disc that will not exceed the lesser of these two distances.
- •Patients who are willing to comply with all study procedures and be available for the duration of the study.
- •Patients or legally authorized representative(s) who are willing and capable of providing informed consent.
排除标准
- •Age <18 years or Age >85 years.
- •Patient with a history of ongoing Atrial Fibrillation (AF).
- •Patient with malignancy or other illness where life expectancy is less than 1 year.
- •Patient not covered by a social security scheme.
- •Patients who are participating in an investigational drug or device study currently.
- •Women of childbearing potential who are, or plan to become pregnant during the time of the study (method of assessment upon physician's discretion).
- •Anything that would place the individual at increased risk or preclude the individual's full compliance with or completion of the study.
- •Any contraindication mentioned in the corresponding IFU:
- •Patients known to have intracardiac thrombi, especially left atrial or left atrial appendage thrombi, demonstrated by echocardiography. Patients known to have a bleeding disorder, untreated ulcer, or any other contraindications to aspirin therapy unless another anti-platelet agent can be administered for 6 months.
- •Anatomy in which the CeraFlexTM PFO device of the required size would interfere with intra-cardiac structure or intra-vascular structure, such as a pulmonary vein, or aorta root.
- •Patients whose heart or vein size is too small to allow TEE probing or catheterization.
- •Patients who are in the condition, e.g. active infection, which would cause them to be poor candidates for cardiac catheterization.
- •Patients known to have sepsis within one month prior to implantation, or any systemic infection that cannot be successfully treated prior to device placement.
- •Patients whose heart does not have enough tissue to secure the device.
- •Patients with hypercoagulation disease.
- •Any patient for whom the radius of the device is greater than the distance from the patent foramen ovale to the aortic root or superior vena cava.
- •No contraindications specified in the SteerEase introducer IFU.
结局指标
主要结局
Procedural success rate
时间窗: Procedure/at discharge or 7 days post-procedure, whichever comes first
Procedure success is defined as a composite of : 1. absence of peri-procedural stroke-related events (ischemic stroke, cryptogenic stroke, or TIA), device embolization, cardiac or vascular perforation, or death, at discharge or 7 days post-procedure, whichever comes first; 2. successful implantation of the device at the procedure.
次要结局
- Rate of stroke related events(From attempted procedure up to 24 months post-implantation)
- Rate of Device Deficiencies(From attempted procedure up to 24 months post-implantation)
- Incidence of Serious Adverse Event(From attempted procedure up to 24 months post-implantation)
- Residual shunt(At procedure, 6 months and 12 months post-implantation)
- Incidence of death(From attempted procedure up to 24 months post-implantation)