Extravascular Lung Water Monitoring by Combined Ultrasound and Bioimpedance as a Guide for Treatment in Hemodialysis Patients

Grigore T. Popa University of Medicine and Pharmacy1 个研究点 分布在 1 个国家目标入组 250 人开始时间: 2013年3月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
250
试验地点
1
主要终点
All-cause mortality

研究概览

简要总结

Patients will be selected from the Dialisys Centers in Iasi, Romania. Patients will be randomized 1:1 to have a dry-weight assessment based on clinical (control) or lung US and bioimpedance (active) guided protocol. In the control group post-dialysis dry weight will be adjusted based on clinical criteria only (blood pressure, presence of edema, intradialytic hypotension, cramps etc.) and in the active group the target weight will be prescribed using lung US and bioimpedance evaluation.

In patients randomized to the active arm of the study, the US B-line score (BLS) will be measured before dialysis and these measurements will be used to titrate ultrafiltration prescription. In patients presenting moderate to severe lung congestion (≥15 BLS pre-dialysis) LUS measurements will be repeated once a week until the treatment goal was achieved (<15 BLS pre-dialysis) and once a month thereafter. The same (monthly) monitoring frequency will be adopted also in patients without pulmonary congestion at pre-dialysis baseline (<15 BLS). Furthermore, the use of the technique is allowed whenever its application is deemed useful to assume clinical decisions by attending physicians. Patients in the active arm of the study without evidence of lung congestion at baseline who developed pulmonary congestion (≥ 15 BLS) during the trial will received the same treatment contemplated for those with lung congestion at baseline during the trial. The treatment goal will be pursued by ultrafiltration intensification realized within the same HD schedule (3 sessions x 4 hours/week) or, if not tolerated, by extra-dialyses, according to individual tolerance and feasibility. In case of clinical hypovolemia (persistent cramps, hypotension etc) additional dry-weight adjustments will be performed according to the bioimpedance measurement, provided that the patients are below 15 BLS. This addition will be necessary in order to be able to increase the dry-weight in patients with a persistent BLS < 15 and avoid under perfusion.

Patients in the control arm of the study will be followed up and managed strictly with standard criteria according to current recommendations (implying optimization of fluids volume control on the basis of clinical criteria and the use of carvedilol, ACE inhibitors/sartans whenever deemed necessary); the use of lung US / bioimpedanc assistance will not be messured in these patients.

The main exclusion criteria will be the presence of severe cardiac failure (NYHA class III-IV), past myocardial infarction, stable or unstable angina and acute coronary syndrome. Due to bioimpedance assessment limitation patients with metallic joint prostheses, cardiac stent or pacemakers, decompensated cirrhosis, pregnancy and limb amputations will be excluded, as BIS cannot be accurately performed in such cases. Due to lung US measurement limitation we will exclude patients with known persistent pleurisy, pulmonary fibrosis or pneumectomy. Other exclusion criteria will be malignancy, active infections, temporary or permanent catheter as a vascular access, mental incompetence and unwillingness to participate in the study.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •patients in hemodialysis for more than 3 months, that have no absolute contraindication for for performing bioimpedance measurements (amputation, stent, pregnancy, severe ascites) and ultrasound lung comets measurements (persistent pleuresia, pulmonary fibrosis, pneumectomy).

排除标准

  • •Patients with metallic joint prostheses, cardiac pacemakers, decompensated cirrhosis, limb amputations and severe conditions with life expectations <1 year

研究组 & 干预措施

active arm of the study

Active Comparator

The number of ultrasound lung comets (ULC) will directly adjust the prescribed post-hemodialysis dry weight. The US B-line score (BLS) will be measured before dialysis. In patients presenting moderate to severe lung congestion (≥15 BLS pre-dialysis) LUS measurements will be repeated once a week until the treatment goal was achieved (<15 BLS pre-dialysis) and once a month thereafter. monthly monitoring frequency will be adopted also in patients without pulmonary congestion (BLS <15). Patients without evidence of lung congestion at baseline who developed pulmonary congestion (≥ 15 BLS) during the trial will received the same treatment contemplated for those with lung congestion at baseline during the trial.

干预措施: Active arm (Other)

Standard care arm

No Intervention

In the control arm of the study, the dry weight will be assessed only clinically.Patients in the control arm of the study will be followed up and managed strictly with standard criteria according to current recommendations (implying optimization of fluids volume control on the basis of clinical criteria and the use of carvedilol, ACE inhibitors/sartans whenever deemed necessary); the use of lung US / bioimpedance assistance was not allowed in these patients.

结局指标

主要结局

All-cause mortality

时间窗: 2 years

次要结局

  • Left ventricular mass measured by echocardiography(2 years)

研究者

发起方
Grigore T. Popa University of Medicine and Pharmacy
申办方类型
Other
责任方
Principal Investigator
主要研究者

Professor Adrian Covic

MD, PhD, FRCP

Grigore T. Popa University of Medicine and Pharmacy

研究点 (1)

Loading locations...