MedPath

iNod™ Ultrasound-Guided Needle Biopsy System Study

Not Applicable
Withdrawn
Conditions
Multiple Pulmonary Nodules
Solitary Pulmonary Nodule
Biopsy, Fine-Needle
Interventions
Device: iNod™ System
Registration Number
NCT05804435
Lead Sponsor
Boston Scientific Corporation
Brief Summary

The purpose of this study is to collect information on the iNod™ System's safety and ability to see the iNod™ biopsy needle in real-time in endobronchial lesions, peripheral lung nodules, or lung masses.

Detailed Description

This post-market study intends to further demonstrate the ability and safety of the iNod™ Ultrasound Guidance System and iNod™ Ultrasound Biopsy needle to perform transbronchial needle biopsy of endobronchial lesions, peripheral lung nodules, or lung masses under real-time ultrasound visualization. This is a prospective, multi-center case series of standard of care peripheral lung nodule biopsy procedures with up to 115 subjects at up to 10 centers.

Recruitment & Eligibility

Status
WITHDRAWN
Sex
All
Target Recruitment
Not specified
Inclusion Criteria
  1. Age 18 years or older.

  2. Subject willing and able to comply with study procedures and provide written informed consent to participate in study.

  3. Subject with a predominantly solid, peripheral lung lesion, 1 cm to 5 cm in diameter measured along its longest cross sectional diameter on axial CT imaging (obtained within 4 weeks per standard of practice) with the intention to undergo a clinically indicated bronchoscopic evaluation under routine clinical care. If the lesion is partially solid (i.e. there is a ground glass component) then the solid portion must make up at least 80% of the lesion.

    a. "Peripheral" lesion in this study will be pragmatically defined as any lesion in the lung parenchyma that the clinician feels cannot be accessed successfully using the convex probe endobronchial ultrasound bronchoscope.

  4. Subject for whom the decision to pursue biopsy has been made by the treating physician and agreed upon by the subject.

Exclusion Criteria
  1. Subjects with pure ground glass opacity or a subsolid target lesion, and/or a ground glass opacity for which less than 80% of the lesion is solid identified by Chest CT.
  2. Subjects who have medical contraindication to undergo conventional flexible or robotic bronchoscopy and standard of care Radial EBUS-guided cytological assessment evaluations, as determined by the investigator.
  3. Subjects with known coagulopathy.
  4. Subjects who are pregnant or nursing mothers.
  5. Subjects who are currently enrolled in another investigational study that would directly interfere with the current study, without prior written approval from the sponsor.
  6. Use of intraprocedural Cone Beam CT, Fixed CT or Augmented fluoroscopy

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
iNod™ SystemiNod™ SystemSubjects with a qualifying lung lesion will have a standard of care Transbronchial Needle Aspiration using the the iNod™ System
Primary Outcome Measures
NameTimeMethod
Proportion of patients where the needle is visualized by the iNOD system inside the lesionProcedure

Successful "Tool in lesion", defined as visualization of the tracheobronchial biopsy needle (TBNA) inside the targeted lesion within the ultrasound field of view.

Adverse EventsProcedure

Proportion of subjects with Adverse Events related to the iNod device and/or study procedure, as well as Adverse Events related to any subsequent crossover procedures.

Secondary Outcome Measures
NameTimeMethod
© Copyright 2025. All Rights Reserved by MedPath