Diagnostic Value of Virtual Bronchoscopic Navigation (VBN) Combined With Endobronchial Ultrasound (EBUS) With a Guide Sheath (GS) for Peripheral Pulmonary Lesions (PPLs) Without Fluoroscopy: a Randomized Controlled Trial
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 436
- 试验地点
- 1
- 主要终点
- The difference of diagnostic value of VBN-EBUS-GS-TBLB with fluoroscopy as compared to VBN-EBUS-GS-TBLB
研究概览
简要总结
The purpose of this study is to evaluate the feasibility, efficacy and safety of transbronchial lung biopsy (TBLB) and bronchial brushing by using virtual bronchoscopic navigation (VBN) combined with endobronchial ultrasound (EBUS) and a Guide Sheath (GS) for the diagnosis of peripheral pulmonary lesions (PPLs) without radiographic fluoroscopy.
详细描述
The investigators evaluate the feasibility, efficacy and safety of transbronchial lung biopsy (TBLB) and bronchial brushing by using virtual bronchoscopic navigation (VBN) combined with endobronchial ultrasound (EBUS) and a Guide Sheath (GS) as a guide for diagnosing peripheral pulmonary lesions (PPLs) without radiographic fluoroscopy.The study is designed as a three centers prospective randomized controlled trial.The participating centers are Department of endoscopy , Shanghai chest Hospital, Shanghai JiaoTong University, China. Department of endoscopy, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences, China. Department of Respiratory Medicine, The First Affiliated Hospital of Guangzhou Medical University, China. Patients are divided into two groups, VBN-EBUS-GS-X-ray group and VBN-EBUS-GS group. Each subject will be randomized to each group. The study is expected to enroll 436 patients at 3 centers.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Individuals eligible for inclusion are patients that the CT scan appearance of the PPLs showed the longest diameter was more than 8mm and non GGO lesions.
排除标准
- •Absence of bronchus leading to or adjacent to the lesion from CT scan
- •Refusal of participation
- •Severe cardiopulmonary dysfunction and other indications that can't receive bronchoscopy
- •Presence of concomitant endobronchial lesion during the brochoscopy procerdure
研究组 & 干预措施
VBN-EBUS-GS group
Fluoroscopy are not used in this group. EBUS and GS are inserted into bronchi in the assistance of VBN. The EBUS probe and GS are confirmed to reach the lesion by EBUS images alone, cytologic and pathologic specimens are obtained without fluoroscopic guidance.
干预措施: VBN (Device)
VBN-EBUS-GS group
Fluoroscopy are not used in this group. EBUS and GS are inserted into bronchi in the assistance of VBN. The EBUS probe and GS are confirmed to reach the lesion by EBUS images alone, cytologic and pathologic specimens are obtained without fluoroscopic guidance.
干预措施: EBUS-GS (Device)
VBN-EBUS-GS-X-ray group
EBUS and GS are inserted into bronchi in the assistance of VBN. The EBUS probe and GS are confirmed to reach the lesion by EBUS images and radiograph fluoroscopy, cytologic and pathologic specimens are obtained with fluoroscopic guidance.
干预措施: VBN (Device)
VBN-EBUS-GS-X-ray group
EBUS and GS are inserted into bronchi in the assistance of VBN. The EBUS probe and GS are confirmed to reach the lesion by EBUS images and radiograph fluoroscopy, cytologic and pathologic specimens are obtained with fluoroscopic guidance.
干预措施: EBUS-GS (Device)
VBN-EBUS-GS-X-ray group
EBUS and GS are inserted into bronchi in the assistance of VBN. The EBUS probe and GS are confirmed to reach the lesion by EBUS images and radiograph fluoroscopy, cytologic and pathologic specimens are obtained with fluoroscopic guidance.
干预措施: X-ray (Device)
结局指标
主要结局
The difference of diagnostic value of VBN-EBUS-GS-TBLB with fluoroscopy as compared to VBN-EBUS-GS-TBLB
时间窗: one year
The diagnostic value means sensitivity and specificity in two groups
次要结局
- The difference of operation time of VBN-EBUS-GS-TBLB with fluoroscopy as compared to VBN-EBUS-GS-TBLB(one year)
- The difference of complications of VBN-EBUS-GS-TBLB with fluoroscopy as compared to VBN-EBUS-GS-TBLB(one year)
研究者
Jiayuan Sun
Director, Department of Endoscopy, Shanghai Chest Hospital
Shanghai Chest Hospital