跳至主要内容
临床试验/NCT03455738
NCT03455738已完成不适用

Dynamic Arterial Elastance Measured by Uncalibrated Pulse Contour Analysis Predicts Arterial Pressure Response to a Decrease in Norepinephrine (VESA) Dynamic Arterial Elastance Measured by Uncalibrated Pulse Contour Analysis

Centre Hospitalier Universitaire, Amiens1 个研究点 分布在 1 个国家目标入组 35 人开始时间: 2016年10月11日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
35
试验地点
1
主要终点
Dynamic arterial elastance (Eadyn) defined as the ratio of PPV/SVV calculated from uncalibrated pulse contour analysis

研究概览

简要总结

Dynamic arterial elastance (Eadyn) has been proposed as an indicator of arterial tone that can predict norepinephrine-dependent arterial pressure. Eadyn is calculated using the ratio of respiratory pulse pressure variation (PPV) over the respiratory stroke volume variation (SVV). Guinot et al demonstrated a decrease in the duration of norepinephrine treatment with the use of Eadyn. To date, studies that have validated Eadyn at bedside have used cardiac output (CO) calibrated pulse contour analysis (PiCCO™, Pulsion™) or oesophageal doppler. Such monitoring systems need dedicated and specific arterial line and venous access that may limit their use at bedside. In addition to CO calibrated pulse contour analysis, CO uncalibrated pulse contour analysis has been developed and is considered less invasive. Nevertheless, one limitation of the latter CO monitoring is inaccuracy of CO measurement in patients who are being treated with norepinephrine. These limitations may affect the predictability of Eadyn. We conducted a prospective study in a university hospital ICU. Patients with vasoplegic syndrome for whom the intensive care physician planned to decrease the norepinephrine dosage were included. Hemodynamic and uncalibrated pulse contour analysis (Volume view, FloTrac, Edwards Lifescience, Irvine) values were obtained before and after decreasing the norepinephrine dosage. Responders were defined by a >10% decrease in mean arterial pressure (MAP).

详细描述

  • Background : Dynamic arterial elastance (Eadyn) has been proposed as an indicator of arterial tone that can predict norepinephrine-dependent arterial pressure. Eadyn is calculated using the ratio of respiratory pulse pressure variation (PPV) over the respiratory stroke volume variation (SVV). Guinot et al demonstrated a decrease in the duration of norepinephrine treatment with the use of Eadyn. To date, studies that have validated Eadyn at bedside have used cardiac output (CO) calibrated pulse contour analysis (PiCCO™, Pulsion™) or oesophageal doppler. Such monitoring systems need dedicated and specific arterial line and venous access that may limit their use at bedside. In addition to CO calibrated pulse contour analysis, CO uncalibrated pulse contour analysis has been developed and is considered less invasive. Nevertheless, one limitation of the latter CO monitoring is inaccuracy of CO measurement in patients who are being treated with norepinephrine. These limitations may affect the predictability of Eadyn.
  • Purpose : To date, no study has evaluated the ability of Eadyn measured by uncalibrated pulse contour analysis to assess arterial pressure response to a decreased dose of norepinephrine. We tested the hypothesis that Eadyn calculated from uncalibrated pulse contour analysis predicts the arterial-pressure response to a norepinephrine decrease in patients treated with norepinephrine

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Inclusion criteria were all consecutive patients with a diagnosis of vasoplegic syndrome, treated with norepinephrine, for whom the attending physician decided to decrease the norepinephrine dosage. The vasoplegic syndrome was defined as persistent arterial hypotension with normal or high cardiac output and low systemic vascular resistance

排除标准

  • Exclusion criteria were patients treated with epinephrine and/or dobutamine, arrhythmia, intra-abdominal hypertension and patients younger than 18 years.

结局指标

主要结局

Dynamic arterial elastance (Eadyn) defined as the ratio of PPV/SVV calculated from uncalibrated pulse contour analysis

时间窗: 60 minutes

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor