跳至主要内容
临床试验/NCT02304276
NCT02304276已完成不适用

18F-Fluoride Assessment of Aortic Bioprosthesis Durability and Outcome

University of Edinburgh0 个研究点目标入组 105 人开始时间: 2015年1月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
105
主要终点
18F-Fluoride uptake in aortic bioprostheses

研究概览

简要总结

This study will evaluate the two main types of replacement tissue heart valve used in current practice, comparing outcomes from surgical aortic valve replacement (AVR) with that of the more recently introduced "key-hole" procedure called transcatheter aortic valve implantation (TAVI). Participants will be recruited at various time points ranging from 1 month to 10 years following valve replacement with either AVR or TAVI. It is thought that progressive calcium (chalk) formation is responsible for the failure of the majority of these valves. All participants will therefore have a PET-CT scan with a special type of "tracer" called 18F-fluoride in order to measure active calcium formation in the valve. They will then have annual clinical follow-up for 5 years and be invited back for a repeat CT scan at 2 years to measure change in calcium burden. This study aims to investigate, firstly, the effects of valve age and type on calcium formation as measured by PET-CT and, secondly, whether this measure of calcium formation can help to predict how long different types of valve will last. If successful, 18F-fluoride PET-CT could become a valuable tool for testing new treatments to improve valve longevity and new valve designs.

详细描述

Aortic stenosis is the commonest form of valve disease in the western world and the leading indication for valve surgery. Bioprosthetic valves are known to degenerate via a process that is predominantly driven by calcification. Transcatheter aortic valve implantation (TAVI) has recently emerged as a less invasive alternative to conventional aortic valve replacement (AVR) surgery. Whilst this technique holds great promise, long-term follow up data are lacking and the longevity of these valves remains to be established.

In this longitudinal, cross-sectional study of 180 subjects with either surgical or transcatheter implanted bioprostheses, this study proposes to look for the earliest signs of active calcification using 18F-fluoride positron emission tomography (PET). During a 5 year follow-up period, this study hopes to demonstrate that 18F-fluoride PET will predict subsequent bioprosthetic valve degeneration and identify patients at risk of premature valve failure. The study also hopes that it will inform about the comparative durability of novel percutaneous valves. If successful, 18F-Fluoride could provide a useful method of assessing novel therapeutic strategies targeted at improving the longevity of bioprostheses and help to guide future valve design.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Parallel
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
40 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •able to provide informed consent
  • •aged over 40 years
  • •patients with a bioprosthetic aortic valve who are due to undergo a redo-surgical aortic valve replacement
  • •able to provide informed consent
  • •aged over 40 years
  • •patients at 1 month (n=10), 2 years (n=20), 5 years (n=20) and 10 years (n=20) following surgical bioprosthetic aortic valve replacement
  • •able to provide informed consent
  • •aged over 40 years
  • •patients at 1 month (n=10), 2 years (n=20) and 5 years (n=20) following transcatheter aortic valve implantation (TAVI) with the Edward's SAPIEN and the COREVALVE.

排除标准

  • •Inability to give informed consent
  • •Pregnancy
  • •Breastfeeding
  • •Claustrophobia
  • •Allergy to iodinated contrast
  • •Liver failure
  • •Chronic kidney disease (with estimated glomerular filtration rate <30 mL/min)
  • •Metastatic malignancy
  • •Paget's disease

研究组 & 干预措施

1 (Explanted valves)

Active Comparator

10 subjects who are due to undergo repeat aortic valve replacement surgery

Investigations:

  1. Baseline 18F-Fluoride PET-CT scan
  2. Retrieval of explanted bioprosthetic aortic valve at time of surgery for analysis

干预措施: 18F-Fluoride PET-CT (Radiation)

2 (AVR)

Experimental

70 subjects with surgical bioprosthetic AVR, to include 10 subjects who have had a valve replacement < 1 month; 20 at 2 years; 20 at 5 years and 20 at >10 years.

Investigations:

  1. Baseline 18F-Fluoride PET-CT scan
  2. Repeat CT calcium score of aortic valve at 2 years
  3. Annual clinical follow-up for 5 years (history, examination, blood tests, ECG and echocardiogram)

干预措施: 18F-Fluoride PET-CT (Radiation)

2 (AVR)

Experimental

70 subjects with surgical bioprosthetic AVR, to include 10 subjects who have had a valve replacement < 1 month; 20 at 2 years; 20 at 5 years and 20 at >10 years.

Investigations:

  1. Baseline 18F-Fluoride PET-CT scan
  2. Repeat CT calcium score of aortic valve at 2 years
  3. Annual clinical follow-up for 5 years (history, examination, blood tests, ECG and echocardiogram)

干预措施: CT calcium score of aortic valve (Radiation)

3 (TAVI)

Experimental

50 subjects who have undergone TAVI with the COREVALVE and 50 subjects with the SAPIEN valve. In each group this will include 10 subjects who have had TAVI < 1 month; 20 at 2 years and 20 at 5 years.

Investigations:

  1. Baseline 18F-Fluoride PET-CT scan
  2. Repeat CT calcium score of aortic valve at 2 years
  3. Annual clinical follow-up for 5 years (history, examination, blood tests, ECG and echocardiogram)

干预措施: 18F-Fluoride PET-CT (Radiation)

3 (TAVI)

Experimental

50 subjects who have undergone TAVI with the COREVALVE and 50 subjects with the SAPIEN valve. In each group this will include 10 subjects who have had TAVI < 1 month; 20 at 2 years and 20 at 5 years.

Investigations:

  1. Baseline 18F-Fluoride PET-CT scan
  2. Repeat CT calcium score of aortic valve at 2 years
  3. Annual clinical follow-up for 5 years (history, examination, blood tests, ECG and echocardiogram)

干预措施: CT calcium score of aortic valve (Radiation)

结局指标

主要结局

18F-Fluoride uptake in aortic bioprostheses

时间窗: Baseline

18F-Fluoride uptake expressed as tissue to background ratio (TBR) in aortic valve bioprostheses of different age and type as measured by PET/CT

次要结局

  • CT calcium score of aortic valve(Baseline and 2 years)
  • Frequency of major adverse cardiovascular events(5 years)
  • Immunohistochemical staining of explanted aortic bioprostheses for marker of calcification(intraoperative)
  • Echocardiographic evaluation of aortic valve function(Baseline, 1 year and 2 years)

研究者

申办方类型
Other
责任方
Sponsor

相似试验