Impact of Infusion of Balanced Crystalloid and Colloid Solutions on Haemostasis in Healthy Male Volunteers- a Randomized Controlled Crossover Trial
试验速览
- 阶段
- 不适用
- 入组人数
- 25
- 试验地点
- 1
- 主要终点
- Rotational thromboelastometry (ROTEM) viscoelastic point-of-care coagulation measurements before and after synthetic colloid infusion
研究概览
简要总结
The project focuses on perioperative bleeding that requires transfusion of blood products and supplementation of intravascular volume with crystalloids and colloids. The implemented fluid therapy affects coagulation and fibrinolysis, depending on the type of fluid used in an intravenous infusion. Massive haemorrhage significantly impacts the perioperative period and postoperative quality of life and requires individualized therapy, rending the ongoing project relevant from the perspective of the patients.
详细描述
Perioperative bleeding is a complication that significantly affects postoperative morbidity and quality of life and increases the patient's risk of death. Massive hemorrhage requires individualized therapy, preferably based on international recommendations. It is necessary to transfuse blood and blood products (red blood cells, freshly frozen plasma, platelets, concentrates of coagulation factors) with simultaneous rational supplementation of the intravascular space using crystalloids and colloids. Usually, these are large volumes that are infused over a short time. Proceedings in the operating room and the intensive care unit environment should stabilize the patient's general condition with the lowest possible risk of complications.
However, it has been shown that transfusions are not free from side effects. Transfusions may result not only from "classic" post-transfusion complications (allergic reactions, haemolytic reactions, infections, electrolyte disturbances) but also from iatrogenically generated disorders in the circulatory system (fluid overload), respiratory ( acute lung injury), and hemostasis (risk of hypercoagulability). It is also known that uncontrolled and unbalanced fluid therapy per se may additionally affect the haemodynamic state, haemostasis, and the immune system.
Thromboelastometry (thromboelastography) is becoming the standard of perioperative haemostasis monitoring. It has been documented that it provides more reliable data than standard laboratory tests, such as fibrinogen concentration, activated clotting time (ACT), kaolin-kephalin (aPTT), prothrombin (PT), or INR index. The test can be performed as the so-called point-of-care test (POC), which reduces the waiting time for the result and facilitates goal-directed therapy.
Little is known about the effects of fluid infusion on physiological haemostasis in healthy subjects who do not have a prior bleeding disorder and who are infused with fluids similarly to resuscitation in massive bleeding. Only singular studies in international literature attempted to answer this vital question. Still, the regular progress in the field of fluid therapy makes the obtained data less and less valuable in clinical practice.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 主要目的
- Prevention
- 盲法
- Single (Participant)
入排标准
- 年龄范围
- 18 Years 至 30 Years(Adult)
- 性别
- Male
- 接受健康志愿者
- 是
入选标准
- •Healthy male volunteers aged 18-30 years
- •The American Society of Anaesthesiologists Physical Status (ASA PS) I risk class
- •Must be able to give informed consent
排除标准
- •Female sex
- •Blood type O
- •A positive history of any acute diseases in the last four weeks
- •Chronic diseases
- •Any diagnosed haemostatic disorders
- •History of anticoagulation
- •Any known bleeding diathesis
- •Any pharmacotherapy in the previous week
- •Participants were informed about the prohibition of drinking alcohol, excessive exercise, and stress on the day before blood sampling
研究组 & 干预措施
Crystalloid infusion
Intravenous (IV) transfusions were performed of a 20ml/kg of a balanced crystalloid solution (Optilyte®, Fresenius Kabi). The infusions were performed through an intravenous cannula (18G) inserted into a vein in the antecubital fossa on the non-dominant limb at 1000 ml/h
干预措施: Standard laboratory coagulation tests and rotational thromboelastometry measurements (Diagnostic Test)
Colloid infusion
Intravenous (IV) transfusions were performed of a 20ml/kg of gelatin 26,500 Da (Geloplasma®, Fresenius Kabi). The infusions were performed through an intravenous cannula (18G) inserted into a vein in the antecubital fossa on the non-dominant limb at 1000 ml/h
干预措施: Standard laboratory coagulation tests and rotational thromboelastometry measurements (Diagnostic Test)
结局指标
主要结局
Rotational thromboelastometry (ROTEM) viscoelastic point-of-care coagulation measurements before and after synthetic colloid infusion
时间窗: 60 minutes
EXTEM, INTEM, FIBTEM assays: * A10: clot firmness amplitude measured after 10 minutes (mm) * A20: clot firmness amplitude measured after 20minutes (mm) * AA: alpha angle (\*) * CFT: clot forming time (s) * CT: clotting time (s) * MCE: maximum clot elasticity * MCF: maximum clot firmness (mm) * ML: maximum lysis (%)
Standard laboratory tests reporting coagulation status before and after synthetic colloid infusion
时间窗: 60 minutes
* fibrinogen concentration (mg/dl) * APTT: activated partial thromboplastin time (s) * PT: prothrombin time (s) * INR: international normalized ratio * PLT: platelet count (10\^3/ul) * MPV: mean platelet volume (fl) * PDW: platelet distribution width (fl) * P-LCR: platelet-large cell ratio (%)
Standard laboratory tests reporting coagulation status before and after balanced crystalloid infusion
时间窗: 60 minutes
* fibrinogen concentration (mg/dl) * APTT: activated partial thromboplastin time (s) * PT: prothrombin time (s) * INR: international normalized ratio * PLT: platelet count (10\^3/ul) * MPV: mean platelet volume (fl) * PDW: platelet distribution width (fl) * P-LCR: platelet-large cell ratio (%)
Standard laboratory tests reporting fibrinolysis status before and after balanced crystalloid infusion
时间窗: 60 minutes
- D-dimer concentration (ug/ml)
Rotational thromboelastometry (ROTEM) viscoelastic point-of-care coagulation measurements before and after balanced crystalloid infusion
时间窗: 60 minutes
EXTEM, INTEM, FIBTEM assays: * A10: clot firmness amplitude measured after 10 minutes (mm) * A20: clot firmness amplitude measured after 20minutes (mm) * AA: alpha angle (\*) * CFT: clot forming time (s) * CT: clotting time (s) * MCE: maximum clot elasticity * MCF: maximum clot firmness (mm) * ML: maximum lysis (%)
Standard laboratory tests reporting fibrinolysis status before and after synthetic colloid infusion
时间窗: 60 minutes
- D-dimer concentration (ug/ml)
次要结局
- Safety outcomes after crystalloid and colloid infusion(28 days)