跳至主要内容
临床试验/NCT04627454
NCT04627454Unknown不适用

Evaluation the Safety and Effectiveness of Dynamic Cervical Implants (DCI) in Treatment of Single Level Cervical Disc Disease

Assiut University0 个研究点目标入组 20 人开始时间: 2020年11月25日最近更新:
适应症
干预措施

试验速览

阶段
不适用
入组人数
20
主要终点
Change of preoperative neck and radicular pain

研究概览

简要总结

  • Evaluation of outcome of DCI in treatment of cervical disc disease to patients admitted to neurosurgery department, Asyut University Hospitals.
  • Give the effective treatment, pain control and can detect the best method could be used.
  • Improve the outcome of these patients and decease rate of recurrence and complications.

详细描述

Anterior cervical decompression and fusion (ACDF) is the traditional method for treating degenerative cervical disc disease, providing satisfactory results in a high proportion of patients. However, stabilization of the treated segment may result in loss of mobility as a functional spinal unit and acceleration of degeneration of the adjacent disc. Re operations may be required to treat complications of fusion, such as recurrent radicular symptoms, non-union, graft collapse, or expulsion. Many previous studies have shown that loss of motion at the fused level is compensated by increased motion at adjacent segments after ACDF, which induces a high rate of degenerative change adjacent to the fused segment. Cervical non-fusion techniques have increasingly been accepted and applied by spine surgeons. As a main component of cervical non-fusion techniques, artificial cervical disc replacement provides good ROM of the cervical spine. Dynamic cervical stabilization with the DCI is a novel treatment approach for cervical disc disease that was initially conceived as a method to combine the potential advantages of fusion and total disc replacement. The first DCI was designed by Matgé in 2002 for treating cervical spondylosis. Paradigm spine introduced the second generation DCIs in 2005. A U-shaped appearance and axial elasticity are two the most significant characteristics. A prospective study by Matgé et al. in 2009 showed that the clinical efficacy was satisfactory after DCI replacement in 102 cases of cervical spondylosis and during a 1-year follow-up; there was neither device migration nor subsidence. The basic concept of the inter-body implant is to maintain a distraction-compression mechanism and so avoid possible collapse of the disc height. This is achieved using the special titanium-alloy DCI, which is bio compatible, available in various sizes, and provided with different foot prints. The U-shaped body provides support and has tooth-like serrations that resist expulsion or retropulsion of the implant when placed into the inter-vertebral space. With the end-plate left intact, osteogenesis and bone fusion are inhibited and no further hetero-topic fusions are supposed to occur. The initial clinical and radio graphic results with the DCI appear promising as an alternative to TDR and ACDF in the treatment of cervical disc disease. It affords maximal neurological improvement, along with maintenance of excellent clinical outcomes. The potential bio-mechanical advantages of DCI include the ability to maintain device-level motion and minimize the development of adjacent-segment disease, while protecting the facet joints from excessive stresses noted with other motion-preserving devices during lateral bending, axial rotation, and extension. The surgical technique included the use of a conventional anterior cervical approach and discectomy. As reported, disc replacement with DCI is a new strategy, in between ACDF & ADR. It is an intermediate solution in the spectrum of management strategies of cervical disc diseases. Immediate dynamic stability with good clinical response and no implant-related morbidity or complications are the main advantages of this implant.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Participant)

入排标准

性别
All
接受健康志愿者
否

入选标准

  • •Patients with single level cervical disc herniation ( C3 - C7 ).
  • •Patients with cervical canal stenosis.
  • •Patients with degenerative disc disease.
  • •Patient with cervical disc disease not responding to medical treatment.
  • •Age of the patient: any age.
  • •Patients fit for surgery.

排除标准

  • •Patients with multilevel cervical disc herniation.
  • •Patients with segmental instability.
  • •Patients with previous cervical spine surgery.
  • •Patients with cervical kyphosis, active infection or known allergy to titanium.

研究组 & 干预措施

dynamic cervical implant

Experimental

dynamic cervical implant in treatment of cervical disc disease

干预措施: Discectomy and insertion of dynamic cervical implant in cervical disc herniation (Procedure)

discectomy

Experimental

insertion of dynamic cervical implant post cervical discectomy single level

干预措施: Discectomy and insertion of dynamic cervical implant in cervical disc herniation (Procedure)

结局指标

主要结局

Change of preoperative neck and radicular pain

时间窗: Two days post operative

Pain measurement post op. To evaluate the effectiveness of DCI ( by Oswestry disability index ) that is measured through 10 questions each is. Scored from 0 to 5. A maximum score of 50, then multiply the results by 2 . Scores are stratified into severity: 0-20 minor disability, 21-40 moderate disability, 41-60 severe disability, 61-80 crippling bback bain, 81-100 either patients are bed ridden or they are exaggerated their symptoms.

Evaluation the motor power

时间窗: Three months

Evaluation patients' motor activity comparing preoperative and postoperative motor power.Assessment of motor function can be graded in patients able to obey commands as follows (right compared to left.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Fahd Abdel Sabour Ahmed Mohammed

Principal investigator, Resident doctor, neurosurgery department

Assiut University

相似试验