A Comparison the Intubation of a Left Sided Double Lumen Tube and the Uniblocker Under the Guidence of Chest Computed Tomography Image
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 60
- 试验地点
- 1
- 主要终点
- The incidence of the optimal position on the first attempt
研究概览
简要总结
One-lung ventilation (OLV) is required for the most thoracic surgery to facilitate surgical visualization by collapsing the lung. The double-lumen tube (DLT) and Uniblocker are the commonly used device for OLV.The objective of our study was to comparison the safety and effectiveness of the intubation of the Left-sided Double-lumen Tube and the Uniblocker under the guidence of chest computed tomography (CT) image.
详细描述
One-lung ventilation (OLV) is required for the most thoracic surgery to facilitate surgical visualization by collapsing the lung. The double-lumen tube (DLT) and Bronchial blockers (BBs) are the commonly used device for OLV.The objective of this study is to comparison the safety and effectiveness of the intubation of the Left-sided Double-lumen Tube and the Uniblocker under the guidence of chest computed tomography (CT) image(the operator count the number of CT slices (slice thickness is 5mm) from vocal cord slice to carina slice to calculate the distance between vocal cord and carina) then measure a distance on the DLT or Uniblocker from the upper edge of the cuff to the mouth side and made a marker on the DLT or Uniblocker.During the intubation the operator insert the DLT or Uniblocker into the trachea via video laryngoscope, after passing the glottis the DLT or Uniblocker are advanced toward the left main-stem bronchus, once the anesthesiologist see the marker on the DLT or the Uniblocker just above the vocal cord stop the insertion.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Factorial
- 主要目的
- Other
- 盲法
- Double (Participant, Outcomes Assessor)
入排标准
- 年龄范围
- 18 Years 至 70 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Adult patients undergoing left side thoracic surgery
排除标准
- •1.Age>70 or <18 years 2.ASA classifications >III 3.BMI >35kg/m2 4.Modified Mallampati classification ≥III 5.Thoracic surgery within the last one month 6.Severe cardiopulmonary disease
研究组 & 干预措施
Uniblocker
The BBs have more advantages than DLT: easier insertion especially in patients with difficult airway18 and no need to exchange the tube when mechanical ventilation is required after surgery
干预措施: Uniblocker (Device)
Left-sided Double-lumen Tube
the double-lumen tube (DLT) is the most commonly used device for OLV
干预措施: Left-sided Double-lumen Tube (Device)
结局指标
主要结局
The incidence of the optimal position on the first attempt
时间窗: 1 year
The incidence of the injuries of bronchi and carina.
时间窗: 1 year
次要结局
- The incidence of lung adequacy collapse(1 year)
- The incidence of Uniblocker displacement(1 year)
- The time for the intubation of Uniblocker or Left-sided Double-lumen Tube(1 year)
- The incidence of sore throat and hoarseness postoperative(1 year)