跳至主要内容
临床试验/NCT06405282
NCT06405282已完成不适用

The Use of Non-Invasive Imaging Devices (NIID) to Detect Temperature Differentiation and Lymphatic/Venous Flow to the Head and Neck During Head Down Tilt Position Before and After Manual Lymphatic Drainage: The NIID Study

Nova Southeastern University1 个研究点 分布在 1 个国家目标入组 15 人开始时间: 2022年4月14日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
15
试验地点
1
主要终点
Percent change (%) in tissue oxygenation saturation level from baseline

研究概览

简要总结

In the weightlessness of space and significant alterations of terrestrial 1 g (1 gravity equivalent) head-to-foot hydrostatic pressure gradients, astronauts experience a dramatic fluid redistribution of ~ 2 liters from the legs to the head and neck within the first 24-48 hours of flight, among other cardiovascular and physiologic system adaptations. After only 4 days in the weightlessness of low earth orbit (LEO), changes can be seen in baroreceptor responsiveness, causing orthostatic hypotension upon subsequent return to Earth. Fluid shifts may also result in headaches, congestion or facial puffiness that can contribute to deteriorating sleep patterns. The ability to manage, mitigate, or offset these fluid shifts is vital to maintain nominal health for short and long duration space flight and potentially improve readaptation to terrestrial gravity or other surface gravity fields, such as the moon or Mars. Fluid shifts towards the cephalic region during microgravity have been speculated to contribute towards spaceflight associated neuro-ocular syndrome (SANS). SANS is a distinct, microgravity-induced phenomenon of neuro-ophthalmic findings observed in astronauts following long-duration spaceflight including choroidal folds, optic disc edema, posterior globe flattening, refractive shift, and cerebral fluid shifts noted to be persistent at 6-month post-flight MRI scans. Thus, noninvasive approaches to studying real-time fluid shifts in weightlessness could serve as critical areas of research to further SANS study and effective countermeasure protocol development. For continuous fluid shift monitoring and management, the goal is to establish baseline assessments utilizing real-time point- of-care noninvasive imaging devices (NIID).

Manual lymphatic drainage (MLD) therapy reduces lymphatic fluid in the affected limb, head, and neck to improve function and prevent progression of fluid build-up. MLD is a therapeutic massage that delivers light pressure through the skin to stimulate lymphatic vessel function. Randomized controlled trials have demonstrated statistically significant improvements in lymphatic function and pain following MLD.

The main objectives of this pilot, retrospective study were to use NIID to examine temperature differential alterations, superficial venous flow patterns (head, neck, upper torso), and venous flow patterns along the lymphatic ventromedial bundles of the medial calves and thighs when in the 6-degree head down tilt (HDT) validated space analogue position and to analyze the effect of MLD therapy administered in the HDT position on lymphatic flow and temperature. HDT is the best validated space analogue currently available for evaluation of fluid redistribution in a timely manner.

详细描述

Under the influence of standard developmental physiology on the Earth's surface (1 g), 70% of body fluids reside below the level of the heart. The lymphatic system has the capacity and capability to transport fluid from distal to proximal in an upward manner, against gravity and tissue pressure gradients, via lymphangion contractility, leg muscle contraction, respiratory and chest wall function, thus augmenting a "suction effect" for pumping lymphatic fluid within the subatmospheric pressure tissue distribution zones (the Guyton principle). Lymphatic drainage of the head and neck must be assisted by gravity, since these regions are above the level of the heart. In the weightlessness of space and significant alterations of terrestrial 1 g head-to-foot hydrostatic pressure gradients, astronauts experience a dramatic fluid redistribution of ~ 2 liters from the legs to the head and neck within the first 24-48 hours of flight, among other cardiovascular and physiologic system adaptations. After only 4 days in the weightlessness of LEO, changes can be seen in baroreceptor responsiveness, causing orthostatic hypotension upon subsequent return to Earth. Fluid shifts may also result in headaches, congestion, or facial puffiness that can contribute to deteriorating sleep patterns. The ability to manage, mitigate, or offset these fluid shifts is vital to maintain nominal health for short and long duration space flight and potentially improve readaptation to terrestrial gravity or other surface gravity fields, such as the moon or Mars. Fluid shifts towards the cephalic region during microgravity have been speculated to contribute towards spaceflight associated neuro-ocular syndrome (SANS). SANS is a distinct, microgravity-induced phenomenon of neuro-ophthalmic findings observed in astronauts following long-duration spaceflight including choroidal folds, optic disc edema, posterior globe flattening, refractive shift, and cerebral fluid shifts noted to be persistent at 6-month post-flight MRI scans. Thus, noninvasive approaches to studying real-time fluid shifts in weightlessness could serve as critical areas of research to further SANS study and effective countermeasure protocol development. For continuous fluid shift monitoring and management, the goal is to establish baseline assessments utilizing real-time point-of-care NIID.

MLD therapy reduces lymphatic fluid in the affected limb, head, and neck to improve function and prevent progression of fluid build-up. MLD is a therapeutic massage that delivers light pressure through the skin to stimulate lymphatic vessel function. Randomized controlled trials have demonstrated statistically significant improvements in lymphatic function and pain following MLD.

The main objectives of this pilot, retrospective case series were to use 4 standard-of-care NIIDs to examine temperature differential alterations, superficial venous flow patterns (head, neck, upper torso), and venous flow patterns along the lymphatic ventromedial bundles of the medial calves and thighs when in the 6-degree HDT space analogue position and to analyze the effect of MLD therapy administered in the HDT position on lymphatic flow and temperature. We hypothesize that dermal venous and lymphatic flow patterns of the head, neck, upper torso, and ventromedial bundle flow patterns shifted to cephalad (dermal interstitial fluid increase) and were reversed following MLD therapy in the 6-degree HDT position. More specifically, MLD therapy could alter lymphatic contractility flow patterns and interstitial fluid, in addition to temperature differentials, in the 6-degree HDT position.

The following imaging devices were used to measure fluid redistribution and temperature in the HDT: near-infrared spectroscopy imaging device (SnapShotNIR, Kent Imaging, Calgary, Canada) to capture perfusion changes through and superficial oxygenation saturation measurements; long-wave infrared and wound imaging device (WoundVision Scout, WoundVision, Indianapolis, IN) to capture thermal images measuring physiological temperature differentiation; Lymphatic fluid scanning device (LymphScanner, Delfin Technologies, Miami, FL, USA) to measure percentage water content [tissue dielectric constant (TDC)] consistent with lymphatic flow patterns and interstitial fluid alterations related to positioning.

研究设计

研究类型
Observational
观察模型
Case Control
时间视角
Retrospective

入排标准

年龄范围
18 Years 至 45 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • Students at Nova Southeastern University
  • Aged 18-45 years
  • Body Mass Index ranging from 18.5 to 24.9
  • No known lymphatic dysfunction
  • Written informed consent

排除标准

  • On blood pressure medications
  • On vasodilation medications
  • Uses any form of nicotine

结局指标

主要结局

Percent change (%) in tissue oxygenation saturation level from baseline

时间窗: Baseline, post-30 minutes, post-60 minutes, post-90 minutes, post-120 minutes, post-150 minutes, post-180 minutes, post-195 minutes (post-MLD), and post-225 minutes (30-minutes-post-MLD).

Tissue oxygenation saturation is an indicator of perfusion changes. NIRS will assess tissue oxygenation at the timepoints listed below. The outcome measure is the percent change in these levels to assess perfusion changes in simulated microgravity; the unit is percentage.

Percent change (%) in TDC level from baseline

时间窗: Baseline, post-30 minutes, post-60 minutes, post-90 minutes, post-120 minutes, post-150 minutes, post-180 minutes, post-195 minutes (post-MLD), and post-225 minutes (30-minutes-post-MLD)

TDC is a measurement of local tissue water content. The lymphatic fluid scanner will assess TDC levels at the timepoints listed below. The outcome measure is the percent change in these levels to assess change in interstitial fluid in simulated microgravity; the unit is percentage.

Percent change (%) in tissue temperature gradient from baseline

时间窗: Baseline,post-30 minutes, post-60 minutes, post-90 minutes, post-120 minutes, post-150 minutes, post-180 minutes, post-195 minutes (post-MLD), and post-225 minutes (30-minutes-post-MLD).

Tissue temperature gradient measures the change in temperature at an area of interest compared to surrounding tissues. Fluid shifts are associated with tissue temperature alterations. LWIT will assess the tissue temperature gradient at the timepoints listed below. The outcome measure is the percent change in temperature gradients to assess changes in thermal energy at an area of interest in simulated microgravity; the unit is percentage.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Heather Barnhart

Professor

Nova Southeastern University

研究点 (1)

Loading locations...

相似试验