NCT04714281已完成不适用
Comparison of Clinical Performance and Hemocompatibility of Dialyzers Applied During Post-dilution Online Hemodiafiltration - eMPORA III Study (Modified POlysulfone membRAne)
适应症
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 82
- 试验地点
- 16
- 主要终点
- Removal rate of β2-microglobulin
研究概览
简要总结
Comparison of the clinical performance and the hemocompatibility profile of different high-flux dialyzers, all applied during post-dilution online hemodiafiltration
详细描述
The primary objective of this study is to test whether the hemodialyzer FX CorAL 600 (applied during post-dilution online hemodiafiltration) is non-inferior or superior to the comparator hemodialyzers FX CorDiax 600 and xevonta Hi 15 in removing ß2-microglobulin.
The secondary objectives of this study are:
- To compare the FX CorAL 600 dialyzer with the comparator hemodialyzers FX CorDiax 600 and xevonta Hi 15 regarding their efficacies in removing other uremic toxins.
- To compare the FX CorAL 600 dialyzer with the comparator hemodialyzers FX CorDiax 600 and xevonta Hi 15 regarding their hemocompatibility profiles.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Sequential
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Minimum age of 18 years
- •Existing informed consent form signed and dated by study patient as well as investigator/authorized physician
- •The patient is legally competent and able to understand the nature, risks, meaning, and consequences of the clinical trial and can subsequently declare her/his consent for participation in the clinical trial (cf. European Medical Device Directive and corresponding national regulations)
- •Patients with a chronic kidney disease stage 5D (end stage renal disease with a glomerular filtration rate of 15 ml/min or less) on hemodiafiltration as extracorporeal renal replacement therapy
- •Study-specific:
- •On online post-dilution hemodiafiltration (HDF), at least 4 h treatment time thrice weekly with FX or FX CorDiax dialyzer ≥ 1 month
- •Vascular access (fistula or graft) which enables blood flow rate ≥ 300 ml/min
排除标准
- •Any condition which could interfere with the patient's ability to comply with the study. This decision is at the discretion of the treating physician and relates to the general stable condition of the patient (e.g. any acute condition, e.g. infection or mental problem which might give reason for concern etc.)
- •Ongoing participation in an interventional clinical study during the preceding 30 days
- •Previous participation in this study
- •Pregnancy (pregnancy test will be conducted at start and end of study with female patients aged < 55 years) or lactation period
- •Patient is not able to give informed consent according to the European Medical Device Directive and corresponding national regulations
- •Study-specific:
- •Recurrent episodes of vascular access failure characterized by e.g. repeated cannulation problems or unstable blood flows within the last 2 months prior to study start (>3 times, respectively)
- •Repeated single needle treatments (>3 times within the last 2 months prior to study start)
- •Catheter as vascular access
- •Unstable patients (due to e.g. acute intercurrent disease like cardiovascular infarction, decompensated heart failure, cerebrovascular accident, severe infection, active malignant disease)
- •Patients with NYHA ≥ 3, COPD (GOLD 2-4), frequent intradialytic symptomatic hypotension
- •Patients with known or suspected allergy to trial product and related products
- •Patients with known inborn or acquired deficiencies of the innate and/or adaptive immune system
- •Patients with acute (use within last 4 weeks) and/or chronic immunosuppressive medication e.g. due to immune-mediated disease including autoimmune diseases, transplantation, or cancer (oral and systemic corticosteroids, calcineurin and mTOR-inhibitors, immunosuppressive monoclonal antibodies, cytotoxic chemotherapy)
- •Planned absence from dialysis unit within the 14 weeks of study duration e.g. due to scheduled hospitalization, holidays or any other reason
- •Active HBV, HCV, HIV, SARS-CoV-2 infection, as well as any other febrile illness
- •Reported SARS-CoV-2 infection with or without symptoms within the 12 weeks before inclusion into the study
- •Unwillingness to undergo repeated SARS-CoV-2 infection testing
结局指标
主要结局
Removal rate of β2-microglobulin
时间窗: t=240 minutes of HDF
Removal rate of β2-microglobulin will be calculated a primary endpoint in blood samples to evaluate the clinical Performance of the dialyzer FXCorAL
次要结局
未报告次要终点
研究者
研究点 (16)
Loading locations...
相似试验
已完成
不适用
Comparison Between HA330 Hemoperfusion Filter Hemodialysis and Conventional High-Flux Hemodialysis FilterRenal DysfunctionHemodialysisSepsisNCT05941624Indonesia University33
已完成
不适用
Hemodialysis Blood Flow and Urea ClearanceEnd Stage Renal Failure on DialysisNCT02484118University of British Columbia24
已完成
2 期
The Effect of Dexmedetomidine and Midazolam on Hemodynamic Indices During AnesthesiaIRCT20110528006617N3Esfahan University of Medical Sciences70
Enrolling By Invitation
不适用
Comparison Between Early-onset and Late-onset Patients With Systemic Lupus Erythematosus.Systemic Lupus ErythematosusNCT06294483Sohag University100
Unknown
不适用
Comparison Studies Comparing Hemodynamic Parameters Provided by the Caretaker Against Respective Gold Standard ReferencesCardiac Output, LowNCT05035719CareTaker Medical LLC60