Effect of Novel Exhalational Delivery System With Fluticasone (EDS-FLU) on Eustachian Tube Dysfunction (ETD) in a Multi-center, Double-Blinded, Placebo-controlled Trial
试验速览
- 阶段
- 2 期
- 状态
- 招募中
- 入组人数
- 80
- 试验地点
- 4
- 主要终点
- 7-Item Eustachian Tube Dysfunction Questionnaire (ETDQ-7)
研究概览
简要总结
Intranasal nasal steroid sprays are the mainstay of treatment for chronic Eustachian tube dysfunction despite having little supportive evidence in the literature. A novel, commercially available nasal spray delivery system is available now for fluticasone that improves its delivery to the nasopharynx. The hypothesis of this study is that fluticasone using the novel spray system is effective for Eustachian tube dysfunction (ETD).
详细描述
BACKGROUND AND RATIONALE
Eustachian tube dysfunction (ETD) can be a symptom of allergic rhinitis, non-allergic rhinitis, or chronic rhinosinusitis. However, it can also be a separate entity with patients displaying no other symptoms of the previously mentioned diseases. There is currently no FDA- approved medication specifically for eustachian tube dysfunction, but most otolaryngologists, allergists, and primary care physicians employ multiple different over-the-counter and prescription medications for its treatment. Most common are oral and topical antihistamines, nasal steroid sprays, topical and oral decongestants, and oral steroids. Nasal steroid sprays, which are FDA-approved for allergic rhinitis, are most frequently used for chronic ETD despite a lack of large clinical trials to support their use. These sprays do have good safety profiles, are frequently available over-the-counter, and do have good data on their efficacy in rhinitis and sinusitis.
Fluticasone nasal spray is available over the counter and is a nasal steroid spray. It is frequently recommended or prescribed for chronic eustachian tube dysfunction. However, its efficacy and the efficacy of all nasal sprays may be limited by the access of previously available sprays into the nasopharynx. The level of evidence for these sprays in chronic ETD is poor overall with only one randomized controlled trial in adults. This study determined no benefit over placebo. In studies determining the deposition of nasal sprays, most of the spray is deposited in the front of the nasal cavity over the inferior turbinates and very little gets into the sinus cavities or nasopharynx. A new exhalational delivery system fluticasone spray (EDS-FLU) has been FDA-approved for patients with chronic rhinosinusitis with polyps. The main difference between this spray and previously available sprays is that it penetrates deeper into the sinuses and also to the nasopharynx, the location of the eustachian tubes. In this system, the user blows out while pumping the spray bottle and his/her breath is the driving force of the spray bottle. Blowing out also elevates the soft palate, seals the nasopharynx, and contains all the spray into the nasal cavity, sinuses, and nasopharynx. In a traditional spray, the soft palate is at resting position, and the spray can pass through the nasal cavity and down into the oropharynx and mouth. This is typically perceived by many users as postnasal drip after the use of nasal sprays. The investigators have previously published a retrospective review of the use of EDS-FLU in patients with at least 1 month of ETD symptoms and found that 79% had improvement more than the minimal clinically important difference. Thirty-six percent of patients normalized with regards to symptoms, and 80% of patients with pre- and post-treatment tympanometry normalized their tympanogram. This study will compare placebo to fluticasone exhalational nasal spray system (Xhance) in a randomized, controlled study.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- Triple (Participant, Care Provider, Investigator)
盲法说明
Patients and investigators will be kept blinded until the end of the study.
入排标准
- 年龄范围
- 18 Years 至 80 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Age greater than or equal to 18 years old, <80 years old
- •Chronic Eustachian tube dysfunction defined as:
- •Symptoms in one or both ears > 3 months AND
- •ETDQ-7 score >14.5 AND
- •Type B, C, or As tympanometry
- •Female subjects of childbearing potential must have a negative urine pregnancy test at screening and throughout the study duration.
排除标准
- •Age <18 years old
- •Known history of otologic surgery (excluding myringotomy or myringotomy tubes)
- •Use of any additional intranasal medication
- •Tympanic membrane perforation
- •Adhesive otitis media
- •Cholesteatoma or significant retraction pocket
- •Middle ear effusion
- •Nasopharyngeal tumor
- •Any history of head and neck cancer
- •Any history of head and neck irradiation
- •Any history of temporomandibular disorder or prior surgery to the temporomandibular joint
- •Any medical condition that the investigator deems inappropriate for enrollment
研究组 & 干预措施
Arm 1 (Placebo)
Arm 1 (placebo) will get placebo spray per day.
干预措施: Placebo Nasal Spray (Other)
Arm 2 (EDS-FLU)
Arm 2 (EDS-FLU) will get 744 mcg of fluticasone propionate per day.
干预措施: Fluticasone Propionate 93 MCG/1 ACTUATION Nasal Spray (Drug)
结局指标
主要结局
7-Item Eustachian Tube Dysfunction Questionnaire (ETDQ-7)
时间窗: visit 3 (week 12)
Eustachian tube dysfunction symptoms measured by the validated quality of life 7-Item Eustachian Tube Dysfunction Questionnaire (ETDQ-7) at visit 3. The scale is from 1 (no problem) to 7 (severe problem).
7-Item Eustachian Tube Dysfunction Questionnaire (ETDQ-7)
时间窗: visit 2 (week 6)
Eustachian tube dysfunction symptoms measured by the validated quality of life 7-Item Eustachian Tube Dysfunction Questionnaire (ETDQ-7) at visit 2. The scale is from 1 (no problem) to 7 (severe problem).
次要结局
未报告次要终点
研究者
Arthur Wu
Principal Investigator, MD
Cedars-Sinai Medical Center