跳至主要内容
临床试验/NCT07411469
NCT07411469招募中不适用

Comparison Between Using Cardiometry and IVC Collapsibility in Predicting Fluid Responsiveness in Hypovolemic Sepsis Patients

Menoufia University1 个研究点 分布在 1 个国家目标入组 60 人开始时间: 2025年5月10日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
招募中
入组人数
60
试验地点
1
主要终点
Septic Shock Evaluation

研究概览

简要总结

Sepsis is a life-threatening condition caused by a dysregulated host response to infection, leading to organ dysfunction. Septic shock, a severe form of sepsis, is characterized by persistent hypotension and cellular/metabolic abnormalities despite adequate fluid resuscitation. It is associated with high mortality rates globally, necessitating timely diagnosis and treatment. Fluid resuscitation and vasopressor use are cornerstones of management, but they must be tailored to the individual to prevent complications such as fluid overload.

详细描述

Predicting fluid responsiveness in critically ill patients is crucial to optimizing fluid therapy. Traditional static measures like central venous pressure (CVP) are unreliable, while dynamic indices such as stroke volume variation (SVV) and pulse pressure variation (PPV) are considered more accurate but limited to specific conditions. Novel, non-invasive tools for predicting fluid responsiveness are particularly valuable in heterogeneous patient populations, including those with spontaneous breathing or arrhythmias.

Non-invasive cardiometry, utilizing advanced hemodynamic monitoring technologies, offers another method to assess fluid responsiveness. By measuring parameters such as stroke volume and cardiac output, non-invasive cardiometry provides real-time insights into a patient's hemodynamic status without the need for invasive procedures. This approach has the potential to guide fluid management effectively, especially in critically ill patients where invasive monitoring may pose additional risks.

Electrical cardiometry (EC) was introduced as a new bio impedance method with the new algorithm for processing the impedance signal to overcome the limitations associated with bio impedance which are used to measure and calculate hemodynamic parameters as cardiac output, cardiac index, SV and systemic vascular resistance index.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 65 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients Diagnosed with Hypotensive Sepsis: Patients must meet the clinical criteria for sepsis according to the Sepsis-3 definitions, including evidence of infection and hypotension despite adequate fluid resuscitation. Hypotension is defined as systolic blood pressure <90 mmHg or mean arterial pressure (MAP) <65 mmHg.
  • BMI ≥18.5 and ≤40 kg/m²: Patients will be included regardless of BMI, as long as it falls within the normal to overweight/obese range. Extremes of BMI (e.g., <18.5 or >40) may be excluded due to the potential influence on peripheral perfusion measurements.
  • American Society of Anesthesiologists (ASA) Physical Status Classification as:
  • ASA Score I-III: Patients with an ASA physical status score of I (healthy patients), II (mild systemic disease), or III (severe systemic disease) will be included. Patients with ASA IV or V (those with severe systemic disease that is a constant threat to life) will be excluded due to potential confounding factors.

排除标准

  • - Cardiac Conditions: Significant valvular heart diseases, such as severe mitral or aortic regurgitation, which can affect hemodynamic assessments.
  • Presence of major cardiac arrhythmias, including atrial fibrillation or frequent ectopic beats, as these can interfere with accurate measurement of fluid responsiveness.
  • - Renal Considerations: Patients undergoing renal replacement therapy or those with end-stage renal disease, as fluid balance and responsiveness may be altered.
  • Pregnancy Hemodynamic changes during pregnancy (e.g., increased cardiac output and altered vascular resistance) differ significantly from septic shock.
  • Patients with a body mass index (BMI) greater than 40 kg/m² Obesity can affect the accuracy of non-invasive monitoring techniques with poor window.

研究组 & 干预措施

Electrical Cardiometry Monitoring

Non-invasive assessment of stroke volume and cardiac output using electrical cardiometry at baseline and after fluid challenge.

干预措施: Cardiometry (Procedure)

Inferior Vena Cava Collapsibility Assessment Group

Thirty patients with septic shock will undergo bedside ultrasound assessment of the inferior vena cava to measure the collapsibility index for evaluation of fluid responsiveness. Measurements will be performed as part of routine clinical monitoring without any alteration to standard clinical management.

干预措施: Cardiometry (Procedure)

结局指标

主要结局

Septic Shock Evaluation

时间窗: Two Hours

Assessment of the participants which suffering from Septic Shock by using Inferior Vena Cava Collapsibility and Electrical Cardiometry for assisting the Fluid Responsiveness

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Ahmed Fared

Resident at Anaesthesia, Intensive Care and Pain Management Department

Menoufia University

研究点 (1)

Loading locations...

相似试验