Skip to main content
Clinical Trials/NCT06583434
NCT06583434
Completed
N/A

Effects of Stabilization-based Pilates Exercise on Gait and Balance in Women With Flexible Pesplanus

Hyun Ju Kim1 site in 1 country22 target enrollmentJanuary 2, 2024

Overview

Phase
N/A
Intervention
Not specified
Conditions
Flexible Flatfoot
Sponsor
Hyun Ju Kim
Enrollment
22
Locations
1
Primary Endpoint
Change in step time
Status
Completed
Last Updated
last year

Overview

Brief Summary

The goal of this clinical trial was to determine if stabilization-based Pilates exercises could improve gait and balance in women with flexible flatfoot.

The main questions it aimed to answer were:

Did Pilates training improve gait parameters in women with flexible flatfoot? Did Pilates training reduce balance instability in these participants?

Researchers compared the Pilates training group to a non-training group. The results showed significant improvements in gait and balance for those who participated in the Pilates training.

Participants:

Completed twice-weekly Pilates sessions for 8 weeks. Underwent pre- and post-intervention assessments of gait and balance.

Detailed Description

Study object This randomized controlled trial aims to assess the effects of stabilization-based Pilates exercises on gait and balance in women with flexible flatfoot. The study focuses on determining whether a specific Pilates program can provide non-invasive rehabilitation for improving gait patterns and reducing balance instability. Participants The study will include 22 healthy women with flexible flatfoot who have no congenital deformities or diseases of the feet, knees and have a navicular drop of ≥10 mm. The participants will be recruited from "Clinical Pilates" studio in Busan city. Women with bilateral flatfoot (n=22) will be randomly allocated to either the Pilates training group (PTG, n=11) or the non-training group (NTG, n=11). Outcome measure gait assessment and data acquisition: Participants undergo several practice walks to familiarize themselves with the gait assessment. Three records are averaged once they show a normal gait pattern. The assessment uses measurements from both legs and is conducted in a non-distracting environment. Seven 3D infrared motion capture cameras (Vicon camera MX-T20, Oxford Metrics, Oxford, UK) and 16 circular reflective markers (14-mm diameter) are used to acquire the data for the gait assessment. The reflective markers are attached to the anterior superior iliac spine, posterior superior iliac spine, lateral mid-thigh, lateral femoral epicondyle, mid-shin, lateral malleolus, second metatarsus, and heel of both the left and right legs. The height, body weight, and width of knee and ankle joints are measured and entered. Gait analysis includes temporal parameters, such as foot-off, step time, stride time, walking speed, and cadence. Kinematic data are collected using Vicon plug-in gait system (Oxford Metrics) at a sampling frequency of 100 Hz. balance assessment and data acquisition: The participants are instructed to stand with their arms crossed in front of their chest, with one leg supported and one leg raised with the knee at a 90° angle. Participants hold that standing position for 40 seconds. Three successful attempts are recorded for each participant. Measurements are taken for both legs, and the participants are given sufficient time to rest between each stage of the experiment. For Center of Pressure (COP) measurement, data from 40 seconds of single leg support on a force platform (AMTI-OR6, Watertown, MA, USA) are utilized. The data are calculated and assessed as time series data. COP sway variability is assessed based on the Root Mean Sqaure (RMS) in Anterior-Posterior (AP) and Medial-Lateral (ML) directions, while AP and ML components of COP velocity and range are also assessed. Kinematic data are collected using the Vicon Plug-in Gait system at a sampling frequency of 100 Hz. Exercise intervention: The exercise intervention consists of two sessions each week, for a total of 16 sessions over an 8-week period. Each training session is structured into eight sets, totaling 50 minites. This includes a 5-min warm-up period, followed by 40-min of the main exercise component, and concluding with a 5-min cool-down phase. The Pilates training is supervised by an instructor with 15 years of experience and a professional Pilates certification. Statistical analysis IBM SPSS Statistics for Windows (version 28.0; IBM Corp., Armonk, N.Y., USA) is used to conduct descriptive statistical analyses, including means and standard deviations. Statistical significance is set at p\<0.05. Differences in mean values between the groups for each temporal parameter will be assessed using independent samples t-tests. Additionally, due to the small sample size, non-parametric tests (Mann-Whitney U test) will be conducted. Furthermore, paired samples t-tests will be used for within-group pre-test and post-test comparisons.

Registry
clinicaltrials.gov
Start Date
January 2, 2024
End Date
March 30, 2024
Last Updated
last year
Study Type
Interventional
Study Design
Parallel
Sex
Female

Investigators

Sponsor
Hyun Ju Kim
Responsible Party
Sponsor Investigator
Principal Investigator

Hyun Ju Kim

Principal Investigator

Busan University of Foreign Studies

Eligibility Criteria

Inclusion Criteria

  • Bilateral navicular drop of ≥10 mm

Exclusion Criteria

  • Clinical diagnosis of Alzheimer's Disease
  • Severe heart conditions (heart failure, myocardial infarction)
  • History of knee, ankle or hip injuries within the last 3 months
  • Chronic lung disease
  • Pregnancy
  • Congenital Foot Deformity ( Polydactyly, Syndactyly)

Outcomes

Primary Outcomes

Change in step time

Time Frame: Baseline and after 8 weeks

Step time was measured in seconds using a 3D motion capture system.

Change in stride time

Time Frame: Baseline and after 8 weeks

Stride time was measured in seconds using a 3D motion capture system.

Change in walking speed

Time Frame: Baseline and after 8 weeks

Walking speed was measured in meters per second using a 3D motion capture system.

Change in cadence

Time Frame: Baseline and after 8 weeks

Cadence was measured in steps per minute using a 3D motion capture system.

Change in foot off

Time Frame: Baseline and after 8 weeks

Foot off was measured as a percentage of the gate cycle using a 3D motion capture system.

Change in balance stability

Time Frame: Baseline and after 8 weeks

Balance was assessed using a single-leg stance test, measuring the center of pressure(COP) sway in both anterior-posterior (AP) and medial-lateral (ML) directions.

Study Sites (1)

Loading locations...

Similar Trials