跳至主要内容
临床试验/NCT06899659
NCT06899659已完成不适用

A Prospective Multi-Center, Randomized Controlled Pre-Market Clinical Trial to Assess the Safety and Effectiveness of the JuggerStitch™ Meniscal Repair Device for Arthroscopic Meniscal Repair

Zimmer Biomet1 个研究点 分布在 1 个国家目标入组 94 人开始时间: 2022年2月14日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
Zimmer Biomet
入组人数
94
试验地点
1
主要终点
Lysholm Knee Score

研究概览

简要总结

This study is a prospective, multi-center, randomized controlled pre-market clinical trial in China to evaluate the safety and efficacy of the JuggerStitch™ Meniscal Repair Device for arthroscopic meniscal repair. The study aims to compare the clinical outcomes of the JuggerStitch™ device with the Fast-Fix 360 Meniscal Repair System in patients with meniscal tears. The primary endpoint is the Lysholm Knee Score at 6 months postoperatively, and secondary endpoints include immediate device success rate, Tegner Activity Score, Visual Analogue Scale (VAS) score for pain, meniscal healing evaluated by MRI, and device-related adverse event rate. The study will enroll 94 subjects across 5 clinical sites.

详细描述

  1. Purpose of the Study The purpose of this study is to evaluate the safety and efficacy of the JuggerStitch™ Meniscal Repair Device for arthroscopic meniscal repair in patients with meniscal tears. The study will compare the clinical outcomes of the JuggerStitch™ device with the Fast-Fix 360 Meniscal Repair System, a well-established device for meniscal repair.
  2. Study Design and Methodology This is a prospective, multi-center, randomized controlled pre-market clinical trial. The study will involve 5 clinical sites and will enroll a total of 94 subjects. Subjects will be randomly assigned to either the investigational group (JuggerStitch™ device) or the control group (Fast-Fix 360 device). The primary endpoint is the Lysholm Knee Score at 6 months postoperatively, and secondary endpoints include immediate device success rate, Tegner Activity Score, VAS score for pain, meniscal healing evaluated by MRI, and device-related adverse event rate.
  3. Inclusion and Exclusion Criteria 1) Inclusion Criteria: Age between 18 and 60 years; Scheduled for meniscal repair with a vertical longitudinal full-thickness tear (e.g., bucket-handle) in the red-red and red-white zones; Able to understand all risks and benefits described in the informed consent form and willing to comply with the rehabilitation and follow-up visits specified in the clinical trial protocol.
  1. Exclusion Criteria: Meniscal tears in the avascular zone of the meniscus; Meniscal tears not suitable for repair due to the degree of damage (marked irregularity and complex tearing) to the meniscus body, including degenerative, radial, horizontal cleavage, flap, and root tears; Multiple ligament injuries of the affected knee joint; Adhesion of the affected knee joint; Planned intraoperative or postoperative intra-articular injection; Articular surface cartilage injury of the targeted knee assessed by the International Cartilage Repair Society (ICRS) is grade 3-4; Kellgren-Lawrence grades of documented radiographic evidence of osteoarthritis (OA) in the affected knee is ≥III; Instability or valgus/varus deformity (>5°) of the affected knee; Acute or chronic, local or systemic infections; Metabolic diseases; Abnormal liver and kidney function (creatinine 3 times higher than the upper limit of normal value or alanine aminotransferase or aspartate aminotransferase 3 times higher than the upper limit of normal value) before operation; History of operation in the affected knee; Acute myocardial infarction or stroke occurred within 6 months before operation; Known allergy to any material (polyethylene, polypropylene, polyester, polyetheretherketone) of the implants; Pregnant or known to be pregnant; Other circumstances that the researchers believe may affect the efficacy and safety evaluation of the investigated medical devices; Currently participating in other clinical trials;
  1. Surgical Procedure The surgical procedure will involve arthroscopic exploration and repair of the meniscal tear using either the JuggerStitch™ device or the Fast-Fix 360 device. The specific steps for each device will be followed according to the manufacturer's instructions and the surgeon's standard operating procedures.

Postoperative Rehabilitation and Follow-up: Postoperative rehabilitation will include the use of an elastic bandage, appropriate massage to prevent blood clots, and guidance on quadriceps isometric contraction and straight leg-raising training. Subjects will be followed up at 3 months, 6 months, and 12 months postoperatively. At each follow-up visit, the Lysholm Knee Score, Tegner Activity Score, and VAS score for pain will be recorded. MRI of the knee joint will be performed at 6 months and 12 months postoperatively to evaluate meniscal healing.

Assessment of Efficacy and Safety: Efficacy will be assessed using the Lysholm Knee Score, Tegner Activity Score, and VAS score for pain. Safety will be assessed by monitoring and recording adverse events, including device-related adverse events, during the follow-up period.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 60 Years(Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Age between 18 and 60 years
  • •Scheduled for meniscal repair with a vertical longitudinal full-thickness tear (e.g., bucket-handle) in the red-red and red-white zones
  • •Able to understand all risks and benefits described in the informed consent form and willing to comply with the rehabilitation and follow-up visits specified in the clinical trial protocol

排除标准

  • •Meniscal tears in the avascular zone of the meniscus
  • •Meniscal tears not suitable for repair due to the degree of damage (marked irregularity and complex tearing) to the meniscus body, including degenerative, radial, horizontal cleavage, flap, and root tears
  • •Multiple ligament injuries of the affected knee joint
  • •Adhesion of the affected knee joint
  • •Planned intraoperative or postoperative intra-articular injection
  • •Articular surface cartilage injury of the targeted knee assessed by the - International Cartilage Repair Society (ICRS) is grade 3-4 Kellgren-Lawrence grades of documented radiographic evidence of osteoarthritis (OA) in the affected knee is ≥III
  • •Instability or valgus/varus deformity (>5°) of the affected knee
  • •Acute or chronic, local or systemic infections
  • •Metabolic diseases
  • •Abnormal liver and kidney function (creatinine 3 times higher than the upper limit of normal value or alanine aminotransferase or aspartate aminotransferase 3 times higher than the upper limit of normal value) before operation
  • •History of operation in the affected knee
  • •Acute myocardial infarction or stroke occurred within 6 months before operation
  • •Known allergy to any material (polyethylene, polypropylene, polyester, polyetheretherketone) of the implants
  • •Pregnant or known to be pregnant
  • •Other circumstances that the researchers believe may affect the efficacy and safety evaluation of the investigated medical devices
  • •Currently participating in other clinical trials

研究组 & 干预措施

Investigational Group

Experimental

Participants in this group will receive the JuggerStitch™ Meniscal Repair Device for arthroscopic meniscal repair. The JuggerStitch™ device is a new all-inside meniscal repair system that consists of a suture device and various auxiliary tools. It is designed to repair vertical longitudinal full-thickness tears (e.g., bucket-handle) in the red-red and red-white zones of the meniscus.

干预措施: JuggerStitch™ Meniscal Repair Device (Device)

Control Group

Experimental

Participants in this group will receive the Fast-Fix 360 Meniscal Repair System for arthroscopic meniscal repair. The Fast-Fix 360 is a well-established all-inside meniscal repair device that consists of a suture and two fixed rods. It is designed to repair meniscal tears in a similar manner to the JuggerStitch™ device.

干预措施: Fast-Fix 360 Meniscal Repair System (Device)

结局指标

主要结局

Lysholm Knee Score

时间窗: Post-op 6 months

The Lysholm Knee Score is a widely used and validated tool for assessing knee function, particularly in patients with meniscal injuries. It evaluates eight aspects of knee function: limp, use of cane or crutches, locking sensation, giving way sensation, pain, swelling, climbing stairs, and squatting. Each aspect is scored on a scale, and the total score ranges from 0 to 100, with higher scores indicating better knee function.

次要结局

  • Immediate Device Success Rate(Intraoperatively)
  • Tegner Activity Score(Post-op 3, 6, and 12 months)
  • Visual Analogue Scale (VAS) Score for Pain(Post-op 3, 6, and 12 months)
  • Meniscal Healing Evaluated by Magnetic Resonance Imaging (MRI)(Post-op 6 and 12 months)

研究者

发起方
Zimmer Biomet
申办方类型
Industry
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验