MedPath

Reliability, Concurrent Validity and Minimal Detectable Change of the Step Up and Down Test in Patients With Total Knee Arthroplasty

Completed
Conditions
Total Knee Arthroplasty
Registration Number
NCT06344182
Lead Sponsor
Dokuz Eylul University
Brief Summary

The aim of the study is to measure the validity and reliability of the StUD test in patients with TKA. Forty-seven patients with primary TKA included in this study. The test-retest reliability of the StUD test was measured with 1-hour interval. Validity was assessed that the 30s Chair Stand Test (30sCS), the Hospital for Special Surgery score (HSS) and Short Form-12 Quality Life Questionnaire (SF-12) were used as comparator instruments.

Detailed Description

The study was designed as test-retest research. This study was approved by the ethics committee of Dokuz Eylul University, Izmir, Turkey. This study was conducted between 2021 and 2022 at the Dokuz Eylul University Hospital Orthopedics Department, Izmir, Turkey. Informed consent was obtained from all participants in accordance with the Declaration of Helsinki.

Sample Size The NCSS Trial and PASS 14 software (NCSS, LLC, Kaysville, Utah USA) was used to conduct the sample size. Power of 0.8 and an alpha level of 0.05 were used. Previous research on StUD in patients with knee Osteoarthritis was noted good test-retest reliability (ICC= 0.87) (G. P. L. Almeida et al., 2021). The test-retest reliability of the current study was thus hypothesized to be excellent. Assuming a %10 attrition rate, a null reliability with ICC=0.75 and expected reliability with ICC=0.90, 47 subjects would be needed.

Participant Forty-seven patients with primary TKA who were operated on by the same surgeon using the paramedian approach were contacted by phone and volunteered to participate in this study. Patients with primary TKA who are at least six months post-surgery were included. Patients were selected and invited to the study by the surgeon and physiotherapist.

Statistical Analysis All data were analyzed using the IBM SPSS Statistics (Version 23.0) software. The Kolmogorov-Smirnov/Shapiro-Wilk tests were used for the determination of the normal distribution. The difference between the pain levels before and after the trials was compared using the Paired Samples T test. The level of significance was determined p \< .05. The correlations between the StUD and 30 CST, HSS, PCS12, and MCS12 were calculated to determine convergent validity. The convergent validity was analyzed based on the Spearman's correlation and was interpreted as follows: 0-0.09 = no correlation; 0.1-0.39 = weak correlation; 0.4-0.59 = moderate correlation; 0.7-0.89 = strong correlation; and 0.9-1 = perfect correlation. Paired samples' t test was used for comparing the difference between the first and second trials of StUD test. The intraclass correlation coefficient (ICC2,1) was used assess the test-retest reliability. The ICC values were interpreted as follows: poor, \<0.5; moderate, 0.5-0.75; good, 0.75-0.9; excellent reliability, \>0.9 (Koo \& Li, 2016). The standard error of measurement (SEM) was calculated as SD×√(1-ICC) , where SD is the pooled standard deviation from the first session. Minimal detectable change (MDC) was calculated at a 95% confidence level (MDC95). MDC95 was calculated according to following formula: MDC95=SEM×1.95×√2. All data were analyzed using the IBM SPSS Statistics (Version 23.0) software

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
47
Inclusion Criteria
  • Patients with primary TKA who are at least six months post-surgery
  • Patients over 40 years of age
Exclusion Criteria
  • having a body mass index (BMI) greater than 40 kg/m2,
  • having had other surgery on a leg with TKA,
  • having symptomatic hip OA,
  • having a history of knee or hip fracture,
  • having a previous orthopedic or neurological disease that prevents stepping

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
Step Up and Down Test2021

In the StUD test, the patient completes maximum number of step-up-down repetitions in 15 seconds.

Secondary Outcome Measures
NameTimeMethod
30 Seconds Chair Stand Test2021

The 30 CST is a valid and reliable performance-based test to assess lower extremity muscle strength in patients with TKA.

Trial Locations

Locations (1)

Dokuz Eylul University

🇹🇷

Izmir, Turkey

© Copyright 2025. All Rights Reserved by MedPath