跳至主要内容
临床试验/NCT05846711
NCT05846711已完成不适用

The Accuracy of Manual BPPV Diagnostics: A Randomized Crossover Study With Comparison of Manual Diagnostic and Diagnostic in TRV Chair, When Using VNG Goggles in Both Scenarios.

Aalborg University Hospital1 个研究点 分布在 1 个国家目标入组 215 人开始时间: 2023年4月12日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
215
试验地点
1
主要终点
Diagnostic Accuracy

研究概览

简要总结

The aim is to investigate the accuracy of manual diagnostics of benign paroxysmal positional vertigo (BPPV) by comparing it to BPPV diagnostics in mechanical rotational chair (TRV chair). VNG (videonystagmography) goggles will be used in both scenarios.

Furthermore, the investigators will examine the importance of angulation and velocity in relation to the diagnostic outcome.

详细描述

Open-label, randomized controlled trial with cross over comparing manual bedside BPPV diagnostics with diagnostics in a mechanical rotational chair (TRV chair) when using VNG goggles in both scenarios.

Patients with a history of positional vertigo will be considered for enrollment and randomized to which diagnostic modality they begin with. Each subject will wait for minimum 30 minutes between the two diagnostics.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Age above 18 years
  • •Classic BPPV-patient history (short lasting (<1 minute) positional rotatory vertigo, no accompanying tinnitus or hearing loss, and no focal neurological findings.
  • •Understand written and spoken Danish

排除标准

  • •Pregnancy
  • •Weight ≥ 150 kg and or Height ≥ 2m
  • •Neck and spine immobility to a degree where MD on examination bed is impossible
  • •Insufficient cooperation during diagnostic testing
  • •Sedative antihistamines taken within the past seven days
  • •Comorbidities: Heart failure (EF < 40), known cerebral aneurysm, cerebrovascular events (<3 months) or dissection disease
  • •Spontaneous or gaze evoked nystagmus

研究组 & 干预措施

Bedside BPPV diagnostics

Active Comparator

Diagnostics of BPPV with manual tests using VNG goggles. The goggles will be added an IMU sensor detecting angulation and velocity (the physician will not get feedback from the sensor during the examination. This will only be used in later analysis).

干预措施: BPPV diagnostic (Diagnostic Test)

Bedside BPPV diagnostics

Active Comparator

Diagnostics of BPPV with manual tests using VNG goggles. The goggles will be added an IMU sensor detecting angulation and velocity (the physician will not get feedback from the sensor during the examination. This will only be used in later analysis).

干预措施: VNG goggles (Device)

Bedside BPPV diagnostics

Active Comparator

Diagnostics of BPPV with manual tests using VNG goggles. The goggles will be added an IMU sensor detecting angulation and velocity (the physician will not get feedback from the sensor during the examination. This will only be used in later analysis).

干预措施: IMU sensor (Device)

Bedside BPPV diagnostics

Active Comparator

Diagnostics of BPPV with manual tests using VNG goggles. The goggles will be added an IMU sensor detecting angulation and velocity (the physician will not get feedback from the sensor during the examination. This will only be used in later analysis).

干预措施: Manual BPPV diagnostics (Procedure)

TRV BPPV diagnostics

Active Comparator

Diagnostics of BPPV using the TRV chair.

干预措施: BPPV diagnostic (Diagnostic Test)

TRV BPPV diagnostics

Active Comparator

Diagnostics of BPPV using the TRV chair.

干预措施: TRV chair (Device)

TRV BPPV diagnostics

Active Comparator

Diagnostics of BPPV using the TRV chair.

干预措施: VNG goggles (Device)

结局指标

主要结局

Diagnostic Accuracy

时间窗: 2 year

Sensitivity, specificity, positive predictive value and negative predictive value of bedside examination (index-test). Gold standard is diagnostics in the TRV chair.

次要结局

  • Head angulation during diagnostic bedside examination.(2 year)
  • Angular velocity during diagnostic bedside examination(2 year)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Malene Hentze Hansen

Principal Investigator

Aalborg University Hospital

研究点 (1)

Loading locations...

相似试验