Effectiveness of a Proprietary Intraluminal Stiffening Wire in Decreasing Procedure Time and Improving Cecal Intubation Rate With Pre-owned Colonoscopes; a Randomized, Controlled Trial

Cornwall Regional Hospital1 个研究点 分布在 1 个国家目标入组 112 人开始时间: 2009年12月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
终止
发起方
入组人数
112
试验地点
1
主要终点
Cecal intubation

研究概览

简要总结

The study aims to determine whether a proprietary, FDA approved stiffening wire improves the efficiency of colonoscopy (that is, decreases the duration of the procedure) and/or enables complete visualization of the colon in a greater proportion of cases (than when the procedure is performed without it) with old, used colonoscopes.

Colonoscopes are designed with a delicate balance between stiffness and flexibility. Stiffness helps to prevent curling (looping) of the colonoscope in those sections of the colon that are not fixed to the wall of the abdominal cavity and flexibility enables successful negotiation of bends or flexures in the colon. As colonoscopes age, they lose stiffness and this makes it very challenging to advance the colonoscope all the way to the cecum (the upper end of the colon). Even when the cecum is successfully reached, it may take an inordinately long time.

In Jamaica, most endoscopists (General Surgeons and Gastroenterologists) use older, pre-owned colonoscopes imported from the USA, because the average patient and local health insurance companies cannot bear the level of fees that would enable cost recovery for new equipment.

The stiffening wires (in two grades of stiffness) used in this study are passed through the biopsy channel of the colonoscope only after its tip has passed the upper end of the descending colon and entered the transverse colon. The device is safe when used as recommended by the manufacturers (and approved by the FDA), and does not appear to increase risk over and above the risk of colonoscopy with the unassisted colonoscope. Although the device clearly improves the stiffness of the colonoscope, there is no research evidence that it actually works in practice, either to improve cecal intubation rate or to decrease procedure time. It is therefore also unclear whether the possible benefit of using the device is achieved if introduced at the first opportunity allowed by the manufacturers or only after difficulty is encountered with the unassisted colonoscope.

In this study, patients are randomly assigned to one of 3 "interventions". One group has colonoscopy performed with the colonoscope alone and the wires are only introduced if there is difficulty advancing the colonoscope after it has passed into the transverse colon ("difficulty" defined as failure to advance the tip of the colonoscope after 5 minutes). In the 2nd and 3rd groups, the assigned wire will be introduced as soon as the colonoscope enters the transverse colon and is removed if "difficulty" is encountered, as defined above. The different phases of colonoscopy will be timed with a stop watch and when a sufficient number of patients has been accrued, the investigator will be able to compare the time it takes to complete the procedure with and without the wires as well as the proportion of cases in which the cecum was reached with and without the assistance of the wires.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Diagnostic
盲法
Single (Participant)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Adults 18 years and older having screening or diagnostic colonoscopy

排除标准

  • Previous hysterectomy
  • Previous radical prostatectomy
  • Clinical presentation or imaging study suggesting presence of lesion that could obstruct passage of colonoscope

研究组 & 干预措施

Stiffening wire #2 transverse colon

Experimental

Colonoscopy is started with the unassisted colonoscope. Stiffening wire #2 is introduced on entry of the tip of the colonoscope into the transverse colon.

干预措施: Colonoscope stiffening device (Device)

Stiffening wire only if difficulty

Experimental

Colonoscopy is performed with the unassisted colonoscope. The stiffening wire is introduced only if there is difficulty advancing the colonoscope and only after the tip has passed the splenic flexure. Difficulty is defined as failure to advance the tip of the scope after 5 minutes of trying.

干预措施: Colonoscope stiffening device (Device)

Stiffening wire #1 transverse colon

Experimental

Colonoscopy is started with the unassisted colonoscope. Stiffening wire #1 is introduced on entry of the tip of the colonoscope into the transverse colon.

干预措施: Colonoscope stiffening device (Device)

结局指标

主要结局

Cecal intubation

时间窗: 10 months

次要结局

  • Time to cecal intubation(10 months)

研究者

发起方
Cornwall Regional Hospital
申办方类型
Other Gov