The purpose of this study is to determinate whether the application of electric currents produce changes in the excitability of alpha moto neurone. Moreover evidence whether the effect of the electric currents can change the tone of the muscle under stimulation in healthy volunteers
详细描述
In the last years several experimental studies have evidenced that the transcutaneous electric nerve stimulation (TENS) in peripheric application can cause a decrease of spasticity and modulation of H-reflexes.
But if the application is in the central nervous system the results are different. So the purpose of this study is quantify the modulation of the excitability of alpha moto neurone when the application of the current is in the central nervous system compared with a sham group.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 主要目的
- Treatment
- 盲法
- Double (Participant, Outcomes Assessor)
入排标准
- 年龄范围
- 18 Years 至 60 Years(Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Participants will be volunteer healthy students of Physiotherapy, University of Castilla - La Mancha, older than 18 years.
排除标准
- •Neuromuscular disease
- •Trauma, surgery or pain affecting the upper limb, shoulder girdle or cervical area
- •Osteosynthesis material in the upper limb
- •Cardiovascular disease
- •Pacemaker or other implanted electrical device
- •Take any drug (NSAIDs, corticosteroids, antidepressants, analgesics, antiepileptics, ...) during the study and in the previous 7 days.
- •Presence of tattoos or other external agent introduced into the treatment or assessment area.
- •Pregnancy
- •Sensitivity disturbance in lower limb
结局指标
主要结局
Post treatment H reflex
时间窗: Immediately after treatment at 40 min.
H-reflex data are obtained by EMG signal. The EMG electrode (SignalConditioningElectrodes v2.3, Delsys Inc., USA) is fixed on triceps surae by the SENIAM protocol (www.seniam.org). The stimulator electrode is fixed on the peroneus nerve, in the popliteal fossa.
Baseline H reflex
时间窗: baseline at 0 min.
H-reflex data are obtained by EMG signal. The EMG electrode (SignalConditioningElectrodes v2.3, Delsys Inc., USA) is fixed on triceps surae by the SENIAM protocol (www.seniam.org). The stimulator electrode is fixed on the peroneus nerve, in the popliteal fossa.
During treatment H reflex
时间窗: During treatment at 33min.
H-reflex data are obtained by EMG signal. The EMG electrode (SignalConditioningElectrodes v2.3, Delsys Inc., USA) is fixed on triceps surae by the SENIAM protocol (www.seniam.org). The stimulator electrode is fixed on the peroneus nerve, in the popliteal fossa.
次要结局
- Muscle tone during treatment(During treatment at 35 min.)
- Baseline muscle tone(Baseline at 0 min.)
- Muscle tone post-treatment(Post-treatment at 42min)