Radiostereometric Analysis (RSA) of the PROFEMUR® Preserve Classic Femoral Components
- Conditions
- OsteoarthritisJoint Disease
- Interventions
- Device: PROFEMUR Preserve Classic Femoral Components
- Registration Number
- NCT02668211
- Lead Sponsor
- MicroPort Orthopedics Inc.
- Brief Summary
MicroPort Orthopedics (MPO) is conducting this study to investigate the primary stability of its PROFEMUR® Preserve Femoral Components using radiostereometric analysis (RSA). RSA allows precise measurement of micromotion around orthopedic implants and hence, may estimate long-term fixation to bone.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- WITHDRAWN
- Sex
- All
- Target Recruitment
- Not specified
- Subject is a candidate for primary THA for osteoarthritis
- Subject is able to undergo primary THA procedure
- Subject is a candidate to be implanted with the specified combination of components
- Subject is willing and able to complete required study visits and assessments
- Subject is willing to sign the approved Informed Consent document
- Subject has any of the following contraindications at the time of the implantation:
- Overt infection;
- Distant foci of infections (which may cause hematogenous spread to the implant site);
- Rapid disease progression as manifested by joint destruction or bone absorption apparent on roentgenogram;
- Skeletally immature (less than 21 years of age at time of surgery);
- Inadequate neuromuscular status (e.g., prior paralysis, fusion, and/or inadequate abductor strength), poor bone stock, poor skin coverage around the joint which would make the procedure unjustifiable;
- Subjects 76 years of age or older
- Subjects with post-traumatic arthritis in the affected hip
- Subjects with rheumatoid arthritis in the affected hip
- Subjects with hip dysplasia in the affected hip
- Subjects with prior arthroplasty of the affected hip
- Subjects that are morbidly obese (BMI > 35)
- Subjects that are immuno-suppressed
- Subjects with known or tested-positive allergy to metals
- Subjects currently enrolled in another clinical investigation which could affect the endpoints of this protocol
- Subjects unwilling or unable to sign the Informed Consent document
- Subjects with substance abuse issues
- Subjects who are incarcerated or have pending incarceration
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description PROFEMUR Preserve RSA PROFEMUR Preserve Classic Femoral Components Single cohort of subjects prospectively implanted with PROFEMUR® Preserve Classic femoral components
- Primary Outcome Measures
Name Time Method Assess the stability of the PROFEMUR® Preserve Classic stem with RSA to estimate its long-term performance. 24 months Assessment of the quantity of migration to determine if the total migration of the stem and cup at 2 years post¬operatively are less than 1.2 mm and 2.6mm, and also less than 0.4mm. Assessment of continuous migration to determine if continuous migration, defined as 0.2mm of motion between 1 and 2 years as measured with RSA exists in the stem and cup.
Assess if migration pattern is greater than 0.2mm between 1 and 2 years 24 months To determine if the wear rate device is substantially less than the scientifically accepted threshold of 0.1 mm/year for osteolysis. The outcomes will be compared to data from the literature, which states that motion greater than 0.2mm between 1 and 2 years suggests an implant is at risk for early loosening.
Determine the migration patterns of the PROFEMUR® Preserve Classic stem with RSA 24 months Assessment of migration in each individual plane (x, y, and z), as measured in mm.
- Secondary Outcome Measures
Name Time Method Patient functional outcomes (HOOS) 24 months The secondary objective is to determine if there is a significant difference in health status and functional outcomes (using the HOOS questionnaire) before and after total hip arthroplasty (THA) using the PROFEMUR® Preserve Femoral Components.
Trial Locations
- Locations (1)
Hopital Maisonneuve Rosemont
🇨🇦Montreal, Quebec, Canada