MedPath

CMR Imaging of Autoimmune Diseases

Active, not recruiting
Conditions
Autoimmune Rheumatologic Disease
Myocarditis
Interventions
Diagnostic Test: Novel Cardiac MRI sequences
Registration Number
NCT04673409
Lead Sponsor
King's College London
Brief Summary

Myocarditis is an important clinical problem which can can occur as a result of viral infections and autoimmune rheumatic diseases. Cardiac MRI is an important non-invasive means of making a diagnosis. However, current MRI techniques have significant limitations. Firstly, in order to create high-quality pictures, patients are required to hold their breath several times for multiple lengths of time. They often struggle with this due to underlying heart/lung problems. This can adversely affect the overall quality and image interpretation. Secondly, current techniques create 2D images that are potentially underestimating the presence and severity of any tissue inflammation/ injury. This may result in inappropriate treatment, particularly for patients with underlying autoimmune systemic disease who require immunosuppression.

Diagnosis by MRI rests on detecting tissue injury through T2 and T1-weighted sequences which detect tissue inflammation and tissue injury. The purpose of this study is to evaluate the diagnostic accuracy of novel 3D free-breathing sequences for T2-weighted and fibrosis/ LGE imaging.

Patients with suspected isolated myocarditis (viral/idiopathic) or myocarditis as part of an autoimmune systemic disease will be recruited to ensure that the novel techniques are tested in a broad spectrum of patients with inflammatory heart muscle disease.

Detailed Description

Not available

Recruitment & Eligibility

Status
ACTIVE_NOT_RECRUITING
Sex
All
Target Recruitment
123
Inclusion Criteria
  • All patients referred for CMR for clinically suspected myocarditis either idiopathic or in the context of autoimmune rheumatic disease.
  • Patients who are able to give informed consent.
Exclusion Criteria
  • Patients in atrial fibrillation.
  • Patients who are unable to give informed consent.
  • Patients whose physical or mental condition indicates that the additional time in the CMR scanner should be minimised.
  • Patients who cannot have CMR due to either contraindications to CMR (e.g., non-conditional intracardiac devices) or contraindications to contrast (e.g., history of allergy to gadolinium).

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
Suspected myocarditis of undefined aetiologyNovel Cardiac MRI sequencesPatients with signs and symptoms of acute myocarditis (as defined by the European Society of Cardiology Working Group on Myocardial and Pericardial Diseases).
Suspected myocarditis with autoimmune rheumatic diseaseNovel Cardiac MRI sequencesPatients with suspected myocarditis due to an underlying AIRD.
Primary Outcome Measures
NameTimeMethod
Diagnostic accuracy of novel versus conventional sequences2 weeks

The CMR diagnosis of myocarditis will be made according to the revised (2018) Lake Louise criteria which mandate an increase in T2 (signal intensity in arbitrary units or absolute values in ms) and a T1-based marker (either absolute T1 in ms or LGE). T2-times and LGE from the novel 3D sequences will be combined as per revised Lake Louise criteria recommendations to make a diagnosis and compared with the conventional clinical sequences. A clinical diagnosis of cardiovascular inflammation will be made by an expert consensus adjudication panel initially based on evaluation of the patient's history and examination findings; ECG; the results of laboratory testing; and ancillary imaging findings. To avoid incorporation bias, the initial assessment will be blinded to tissue characterisation findings, and the classification will be compared between new and old methods using ROC analysis and the DeLong test.

Secondary Outcome Measures
NameTimeMethod
Acquisition time for both conventional and novel sequences versus conventional sequences2 weeks
Proportion of diagnostic images with novel versus conventional sequences2 weeks
Quantitative accuracy and precision of novel 3D sequences compared with conventional sequences2 weeks

The accuracy (bias) and precision (95% limits of agreement) of the novel 3D quantitative T2-mapping sequence will be assessed with the conventional 2D-values as a reference comparator using the methods of Bland and Altman. This will be used to derive the bias in measured T2 times in ms and the corresponding 95% limits of agreement (in ms).

Trial Locations

Locations (1)

Guy's and St Thomas' NHS Foundation Trust

🇬🇧

London, United Kingdom

© Copyright 2025. All Rights Reserved by MedPath