跳至主要内容
临床试验/NCT06479486
NCT06479486已完成不适用

Clinimetric Properties of Performance-based Measures of Physical Function in Patients With COPD: a Comparison of Clinimetric Properties of Four Tools

Riphah International University2 个研究点 分布在 1 个国家目标入组 50 人开始时间: 2024年7月15日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
50
试验地点
2
主要终点
2MWT (Two-Minute Walk Test)

研究概览

简要总结

A COPD (Chronic obstructive pulmonary disease), is a group of progressive lung diseases. COPD is a preventable and treatable respiratory disorder largely caused by smoking and long term exposure to chemical irritants. This study aims to provide essential insights into the reliability, validity, responsiveness and Interpretability of such tests, enabling healthcare professionals to make informed decisions about patient recovery progress and the optimization of rehabilitation protocols.

详细描述

A COPD (Chronic obstructive pulmonary disease), is a group of progressive lung diseases, a preventable and treatable respiratory disorder largely caused by smoking and long term exposure to chemical irritants. COPD affects the respiratory system and is progressive, which can result in a number of difficulties or impairments. ) Effect on Daily Activities, Work Limitations, Fatigue Muscle Weakness, Breathlessness and Reduced Exercise Capacity, and Impaired Quality of Life. Pulmonary rehabilitation is a comprehensive course that helps people with chronic respiratory illnesses, such as COPD, improve their overall health and quality of life. Clinimetric properties of four distinct tools designed for assessing performance-based physical functional outcomes following COPD patients surgery. 6 Minute Walk Test (6MWT), 2 minute Walk test (2MWT), and Timed Up and GO (TUG), 30sec sit to stand test (30sec STS) will be assessed to determine any changes in their functionality test.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
40 Years 至 65 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Diagnosed cases of COPD (FEV1/FVC < 0.70).
  • Both genders
  • Clinically stable
  • Age 40-65 years

排除标准

  • Disease exacerbation in last 4 weeks
  • Co-existing respiratory or any other condition
  • Inability to perform tests due to cognitive or any physical limitations

结局指标

主要结局

2MWT (Two-Minute Walk Test)

时间窗: 6 week

The 2MWT is a functional exercise test designed to evaluate an individual's aerobic capacity and endurance over a shorter duration compared to the 6MWT.

Timed Up and GO (TUG)

时间窗: 6 week

It is designed to assess an individual's mobility and requires the participant to stand up from a seated position, walk a distance of three meters, turn around, walk back to the chair, and sit down.

30 seconds sit to stand test (30SSTS):

时间窗: 6 week

Used to assess lower extremity strength, balance, and functional capacity in patients with chronic obstructive pulmonary disease (COPD). It involves measuring the number of times a patient can rise from a seated position to a full standing position and then return to sitting within a 30-second period. The test is typically conducted in a chair with a standardized height and armrest comapred TUG test

6MWT (Six-Minute Walk Test)

时间窗: 6 week

A six-minute walk test to assess your fitness or functional condition. Using a pulse oximeter, the researchers will take your blood pressure, pulse, and oxygen saturation before you start walking. The following instructions will be given to participants. The competitors will walk as close to a chair or cone as they can for six minutes at their regular pace. After that, they will turn around and continue walking back and forth for an additional six minutes. It was shown that this test had good test-retest reliability.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验