A Randomized Control Trial Comparing Two Methods of Delivering Continuous Positive Airway Pressure (CPAP), Infant Flow System CPAP and Bubble CPAP, in Supporting Successful Extubation of Infants of Birth Weights Less Than or Equal to 1500 Grams at Birth (C2CPAP)

Sunnybrook Health Sciences Centre1 site in 1 country76 target enrollmentSeptember 2003

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
Premature Birth
Sponsor
Sunnybrook Health Sciences Centre
Enrollment
76
Locations
1
Primary Endpoint
failure of extubation as defined by the following: pH < 7.25 and PCO2 > 65 (or an increase of 15 mmHg from pre-extubation), a sustained (> 1 hour) increase in FiO2 of .15 (as compared to pre-extubation) or significant apno
Last Updated
19 years ago

Overview

Brief Summary

Continuous positive airway pressure (CPAP) has been used successfully to promote extubation in the premature infant population. The two methods of CPAP to be examined are currently used by many institutions, yet no study has compared these methods to determine which is better in the population of newborns < 1500 grams (birth weight) at supporting extubation. This randomised controlled study will examine two types of CPAP: the Infant Flow System and the Bubble CPAP. This randomised controlled, single site, clinical study is to determine whether the Bubble CPAP or the Infant Flow System (IFS) CPAP is more effective at supporting the extubation in infants of birth weights < 1500 grams. Seventy-six infants will be randomised, immediately prior to extubation, to IFS or Bubble CPAP of 5 cmH2O. The primary outcome is successful extubation, defined as not reaching failure criteria for the 7 days post-extubation. Failure criteria are defined as pH < 7.25 and PCO2 > 65 mmHg or a sustained increase in FiO2 of 0.15.

Detailed Description

Background: Continuous Positive Airway Pressure (CPAP) has been used successfully to promote extubation in the premature infant population (Davis \& Henderson-Smart, 2002). The two methods of CPAP to be examined are used by many institutions, yet no study has compared these methods to determine which is better in the population of newborns \< 1500 grams (birth weight) at supporting extubation. This study may have cost savings implications. If bubble CPAP is shown to be as effective in this application neonatal intensive care units (NICUs) will have a more affordable option of providing effective CPAP. Methods: This randomised controlled, single site, clinical study is to determine if Bubble CPAP or Infant Flow System (IFS) CPAP is more effective at supporting extubation in infants of birth weights \< 1500 grams. Seventy-six infants will be randomised immediately prior to extubation to IFS or Bubble CPAP of 5 cmH2O. The primary outcome is successful extubation, defined as not reaching failure criteria for the 7 days post-extubation. Failure criteria are defined as pH \< 7.25 and PCO2 \> 65 mmHg or a sustained increase in FiO2 of 0.15. Participants: Parents/guardians of eligible infants will be approached and given information regarding the study, and any questions answered. They will then be allowed to consider study participation in private. The recruiter will return at an agreed time and informed consent will be obtained from those agreeing to participate. Parents will be approached in accordance with the guidelines of the NICU @ SWCHSC. Infants are eligible if birth weight \< 1500 grams, are to be extubated to CPAP and have no known airway anomalies, or suspected genetic anomalies. Analysis: Multiple ANOVA analysis will be used for continuous variables, chi-square for categorical variables, including primary outcome. Conclusion: The results of this study will determine which method of CPAP is the best method of supporting extubation in the \< 1500 g infant.

Registry
clinicaltrials.gov
Start Date
September 2003
End Date
TBD
Last Updated
19 years ago
Study Type
Interventional
Study Design
Parallel
Sex
All

Investigators

Eligibility Criteria

Inclusion Criteria

  • Intubated infant
  • ≤ 1500 grams at birth
  • Decision to extubate to CPAP made by the clinical team
  • Written informed consent obtained

Exclusion Criteria

  • Have known airway anomalies
  • Have grade III or IV or periventricular leukomalacia
  • Have known or suspected genetic syndromes

Outcomes

Primary Outcomes

failure of extubation as defined by the following: pH < 7.25 and PCO2 > 65 (or an increase of 15 mmHg from pre-extubation), a sustained (> 1 hour) increase in FiO2 of .15 (as compared to pre-extubation) or significant apno

Secondary Outcomes

  • reintubation
  • length of time in days on CPAP
  • corrected gestational age at cessation of CPAP
  • average weight gain on CPAP
  • assessment of pain will