Skip to main content
Clinical Trials/NCT03023475
NCT03023475
Completed
Not Applicable

Prospective Randomized Comparison of Two Different Endoscopic Radial Artery Harvesting Devices

Kerckhoff Klinik1 site in 1 country100 target enrollmentFebruary 1, 2017

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
CABG Graft Integrity
Sponsor
Kerckhoff Klinik
Enrollment
100
Locations
1
Primary Endpoint
Endothelial integrity of the radial artery using histological examination.
Status
Completed
Last Updated
6 years ago

Overview

Brief Summary

Endoscopic radial artery harvesting in coronary bypass surgery is routinely performed by the investigators. In this study, the investigators want to compare the MiFusion TLS2 (Endotrust GmbH, Germany) device to the LigaSure Maryland Jaw (Medtronic, USA). The vessel harvesting is performed in the standard fashion according to the institutional routine. The patients are randomized preoperatively to one of the devices. The proximal end of the radial artery will be preserved and deep-frozen for histological assessment. Endothelial integrity will be investigated using Hematoxylin-Eosin, CD31 and endothelial nitrogen monoxide synthase.

Registry
clinicaltrials.gov
Start Date
February 1, 2017
End Date
February 28, 2018
Last Updated
6 years ago
Study Type
Interventional
Study Design
Parallel
Sex
All

Investigators

Responsible Party
Sponsor

Eligibility Criteria

Inclusion Criteria

  • all adult patients undergoing CABG using the radial artery
  • capability to give informed consent

Exclusion Criteria

  • no specific exclusion criteria

Outcomes

Primary Outcomes

Endothelial integrity of the radial artery using histological examination.

Time Frame: Through study completion, an average of 1 year.

Secondary Outcomes

  • Hemostasis in the arm indicated by bleeding from radial artery side branches or veins in the arm.(Intraoperatively and directly after vessel harvesting the arm is controlled using the endoscope and bleeding can be detected during this control. End of surgery is end of this outcome parameter.)
  • Accuracy of vessel sealing, if side branches of the radial artery are bleeding after blood insufflation, additional clips have to placed at the side branch.(The blood insufflation is performed immediately after vessel harvesting and leaks can be detected.)
  • Harvesting time(The harvesting time will be measured during the vessel harvesting surgery.)

Study Sites (1)

Loading locations...

Similar Trials