Comparability of Keratometry of VERION Image Guided System With Established Measuring Devices
- Conditions
- Healthy
- Interventions
- Device: Slit lampDevice: AutorefractorDevice: IOLMaster 500Device: Pentacam HRDevice: LenStar LS900Device: VERION Image Guided System
- Registration Number
- NCT02377154
- Lead Sponsor
- Heidelberg University
- Brief Summary
The purpose of this study is to determine if the keratometric functions of the VERION Image Guided System are comparable to those of established keratometric devices (IOLMaster 500, Pentacam HR, LenStar LS900). Calculated intraocular lenses (IOLs) are compared as a clinical consequence of the biometric measurement for IOLMaster 500, LenStar LS900 and VERION Image Guided System.
In addition the comfort and duration of examination in the different devices is evaluated.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 150
- All interested individuals
- Full legal capacity
- Pre-existing or actual ocular disease or pathology, history of ocular surgery
- Contact lens wear 2 weeks before examination
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description Opthalmologically healthy individuals IOLMaster 500 Slit lamp, Autorefractor, IOLMaster 500, Pentacam HR, LenStar LS900, VERION Image Guided System Opthalmologically healthy individuals Slit lamp Slit lamp, Autorefractor, IOLMaster 500, Pentacam HR, LenStar LS900, VERION Image Guided System Opthalmologically healthy individuals Pentacam HR Slit lamp, Autorefractor, IOLMaster 500, Pentacam HR, LenStar LS900, VERION Image Guided System Opthalmologically healthy individuals Autorefractor Slit lamp, Autorefractor, IOLMaster 500, Pentacam HR, LenStar LS900, VERION Image Guided System Opthalmologically healthy individuals LenStar LS900 Slit lamp, Autorefractor, IOLMaster 500, Pentacam HR, LenStar LS900, VERION Image Guided System Opthalmologically healthy individuals VERION Image Guided System Slit lamp, Autorefractor, IOLMaster 500, Pentacam HR, LenStar LS900, VERION Image Guided System
- Primary Outcome Measures
Name Time Method Accuracy of repeatability of keratometry as performed by VERION Image Guided System 3 immediate repetitions at study visit (study consists of 1 visit only)
- Secondary Outcome Measures
Name Time Method Subjective comfort for test persons as evaluated by questionnaire Immediately after study visit (study consists of 1 visit only) Duration of measurements of each keratometric device as taken by stopwatch During measurements from placement of head until completion Keratometric values as measured by IOLMaster 500, Pentacam HR, LenStar LS900, VERION Image Guided System At study visit (study consists of 1 visit only) White-to-White distance as measured by IOLMaster 500, Pentacam HR, LenStar LS900, VERION Image Guided System At study visit (study consists of 1 visit only) Intraocular lens calculation as performed by IOLMaster 500, LenStar LS900, VERION Image Guided System Immediately after measurement
Trial Locations
- Locations (1)
Department of ophthalmology, University of Heidelberg
🇩🇪Heidelberg, Baden-Wuerttemberg, Germany