Phase 1 Study of the Aeris Bronchoscopic Lung Volume Reduction (BLVR) System in Patients With Advanced Heterogeneous Emphysema

Aeris Therapeutics4 个研究点 分布在 1 个国家目标入组 6 人开始时间: 2005年4月1日最近更新:
适应症

试验速览

阶段
1 期
状态
已完成
发起方
入组人数
6
试验地点
4
主要终点
SAEs - Safety

研究概览

简要总结

The purpose of this study is to determine whether the Aeris Bronchoscopic Lung Volume Reduction (BLVR) System is safe in patients with advanced emphysema.

详细描述

Patients with emphysema currently have limited treatment choices. Many patients are treated with steroids and inhaled medications, which often provide little or no benefit. Recently, lung volume reduction surgery has become an accepted therapy for emphysema. Lung volume reduction surgery involves the removal of a diseased portion of the lung, which enables the remaining, healthier portions of the lung to function better. This procedure, although effective, is complicated and risky.

Aeris Therapeutics has developed the Aeris Bronchoscopic Lung Volume Reduction System for treatment of patients with advanced emphysema. The Aeris BLVR System is designed to reduce lung volume without surgery. Patients are treated under anesthesia using a bronchoscope to direct treatment to the most damaged areas of the lung. The treatment is expected to reduce lung volume by shrinking the diseased areas of the lung. The purpose of the current study is to find out whether the Aeris BLVR System is safe in patients with advanced emphysema. The risks associated with the treatment are expected to be similar to those associated with general anesthesia and bronchoscopy.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Advanced emphysema
  • Limited exercise capacity and persistent symptoms despite medical therapy
  • Age between 18 and 75
  • No significant heart, kidney or liver disease
  • Willingness and ability to tolerate bronchoscopy
  • No prior Lung Volume Reduction Surgery or Lung Transplantation
  • Screening test results indicating that the procedure is appropriate

排除标准

  • 未提供

结局指标

主要结局

SAEs - Safety

时间窗: 1 year post treatment

次要结局

  • PFTs(12 weeks post treatment)
  • Dyspnea(12 weeks post treatment)
  • Exercise capacity(12 weeks post treatment)
  • QOL(12 weeks post treatment)