Skip to main content
Clinical Trials/NCT05587244
NCT05587244
Enrolling by Invitation
N/A

Multicenter, Prospective Post-Market Clinical Follow-Up Study of the G7® Freedom Constrained Vivacit-E® Liners

Zimmer Biomet10 sites in 1 country202 target enrollmentMay 8, 2023

Overview

Phase
N/A
Intervention
Not specified
Conditions
Osteoarthritis, Hip
Sponsor
Zimmer Biomet
Enrollment
202
Locations
10
Primary Endpoint
Survival of the study device
Status
Enrolling by Invitation
Last Updated
6 months ago

Overview

Brief Summary

The main objectives of this study are to confirm the long-term safety, performance, and clinical benefits of the G7 Freedom Constrained Vivacit-E Acetabular Liners in primary and revision total hip arthroplasty.

Detailed Description

The main objectives of this study are to confirm the long-term safety, performance, and clinical benefits of the G7 Freedom Constrained Vivacit-E Acetabular Liners in primary and revision total hip arthroplasty. The primary endpoint is defined by the survival of the implant system at 10 years, which is based on removal of the study device and will be determined using the Kaplan-Meier method. The safety of the system will be assessed by monitoring the frequency and incidence of adverse events. Relation of the events to the implant, instrumentation and/or procedure should be specified. The secondary endpoints are the assessment of performance and clinical benefits by recording patient-reported clinical outcomes measures (PROMs) as well as radiographic outcomes (if available). The G7 Vivacit-E Freedom Constrained Liner is indicated for use (per IFU) as a component of a total hip prosthesis in primary and revision patients at high risk of dislocation due to a history of prior dislocation, bone loss, joint or soft tissue laxity, neuromuscular disease, or intraoperative instability, and for whom all other options to constrained acetabular components have been considered.

Registry
clinicaltrials.gov
Start Date
May 8, 2023
End Date
December 1, 2038
Last Updated
6 months ago
Study Type
Interventional
Study Design
Single Group
Sex
All

Investigators

Responsible Party
Sponsor

Eligibility Criteria

Inclusion Criteria

  • Patient is 18 to 80 years of age, inclusive
  • Patient is skeletally mature
  • Patient qualifies for unilateral total hip arthroplasty based on physical exam and medical history including at least one of the following:
  • Non-inflammatory degenerative joint disease, including osteoarthritis and avascular necrosis
  • Rheumatoid arthritis
  • High risk for dislocation
  • Undergoing revision hip arthroplasty
  • Correction of functional deformity
  • In need of treatment of non-union, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement, unmanageable by other techniques
  • Patient is willing and able to complete scheduled follow-up evaluations as described in the protocol and Informed Consent

Exclusion Criteria

  • Patient is septic, has an active infection or has osteomyelitis at the affected joint
  • Patient has significant osteoporosis as defined by treating surgeon
  • Patient has metabolic disorder(s) which may impair bone formation
  • Patient has osteomalacia
  • Patient has distant foci of infections which may spread to the implant site
  • Patient has rapid joint destruction, marked bone loss or bone resorption on pre-operative radiographs
  • Patient underwent contralateral THA within 3 months of planned index procedure or has a contralateral THA planned within 3 months of the index procedure
  • Patient is undergoing simultaneous bilateral THA
  • Patient has vascular insufficiency, muscular atrophy at the implant site or neuromuscular disease which might jeopardize the outcome of the surgery.
  • In the opinion of the investigator, patient has any concomitant disease which is likely to jeopardize the functioning or success of the implant

Outcomes

Primary Outcomes

Survival of the study device

Time Frame: 10 years

Survival (whether or not it is still implanted in the subject) determined using Kaplan Meier method.

Secondary Outcomes

  • Incidence of treatment-emergent Adverse Events (safety)(10 years)
  • Radiographic Performance evaluating atrophy/hypertrophy at 5 years follow-up(5 Years)
  • Radiographic Performance evaluating device fracture at 5 years follow-up(5 Years)
  • Pain and Functional Performance - Oxford Hip Score(10 years)
  • Radiographic Performance evaluating component migration at 5 years follow-up(5 Years)
  • Pain and Functional Performance - Modified Harris Hip Score(10 years)
  • Radiographic Performance evaluating radiolucency at 5 years follow-up(5 Years)
  • Radiographic Performance evaluating osteolysis at 5 years follow-up(5 Years)
  • Euroqol Patient Quality of life measured at 2 years follow-up (EQ-5D-5L)(10 Years)
  • Radiographic Performance evaluating heterotopic ossification at 5 years follow-up(5 Years)

Study Sites (10)

Loading locations...

Similar Trials