NCT00325832已完成4 期
Conventional Versus Automated Measurement of Blood Pressure in the Office (The CAMBO Study)
适应症
试验速览
- 阶段
- 4 期
- 状态
- 已完成
- 入组人数
- 750
- 试验地点
- 2
- 主要终点
- ambulatory blood pressure
研究概览
简要总结
To determine if the use of automated office blood pressure readings can improve management of systolic hypertension in routine clinical practice. Automated office SBP recordings in routine clinical practice using the BpTRU device will reflect more accurately the mean awake ambulatory systolic BP than will manual BP readings taken with conventional mercury sphygmomanometry. This should lead to improvements in the management of systolic hypertension with optimization of drug therapy in practices using the BpTRU device.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Factorial
- 盲法
- None
入排标准
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Both treated and untreated patients with systolic hypertension under routine FP care
- •For untreated patients, routine office SBP as measured by the patient's FP at the last routine office visit using a mercury device must have SBP ≥ 160 mmHg and DBP <= 95 mmHg
- •For patients already receiving antihypertensive therapy, the last routine office BP as measured by the patient's FP using mercury sphygmomanometry must be SBP ≥ 140 mmHg and DBP <= 90 mmHg
排除标准
- •Presence of target organ damage such as MI, stroke, and serum creatinine twice normal
- •Diabetes mellitus treated with insulin or oral hypoglycemic therapy
- •Secondary hypertension
- •Participation in another research study involving measurement of BP
- •Patient's insistence on using self BP measurement outside of the study
- •Any conditions or circumstances which might preclude the successful completion of the study
结局指标
主要结局
ambulatory blood pressure
次要结局
未报告次要终点
研究者
研究点 (2)
Loading locations...
相似试验
已完成
不适用
Comparison of Blood Pressure Measurement With an Omron HEM-907 Device in a Clinical Setting and a Research SettingHypertensionNCT03360669Institut de Recherches Cliniques de Montreal70
撤回
不适用
Where Should Automated Blood Pressures be Done in Primary Care Offices?HypertensionNCT01538004North Toronto Primary Care Research Network
已完成
不适用
Accuracy Assessment of an Automatic Blood Pressure Measurement Device in Pregnant WomenPre EclampsiaNCT02319174William Marsh Rice University43
已完成
不适用
Accuracy Assessment of an Automatic Blood Pressure Measurement Device in Adult VolunteersPre EclampsiaNCT02267577William Marsh Rice University90
Unknown
不适用
Comparisonbetween Primary Hypertension Monitoring Methods for Detection of Early Kidney DysfunctionPrimary HypertensionNCT03491813Assiut University102