Tissue Oxygen Use With Combined Arteriovenous Noninvasive Oximetry
- Conditions
- Oxygen Consumption
- Interventions
- Device: Finger pulse oximetry probeDevice: Transreflectance oximetry probe
- Registration Number
- NCT06072755
- Lead Sponsor
- University of Wisconsin, Madison
- Brief Summary
The goal of this observational study is to find out if researchers can measure oxygen consumption in the body without having to draw blood from lines in arteries and central veins.
Participants will undergo measurements of arterial blood oxygen saturation using both finger and neck pulse oximeters.
- Detailed Description
TOUCAN-1 is a study to estimate the accuracy and precision of pulse oximetry as a noninvasive tool for oxygen consumption measurement. Researchers will use a pair of commercially-available, noninvasive pulse oximeters to estimate the oxygen saturation of blood in the internal jugular vein, and compare it to the directly measured oxygen saturation in sampled jugular blood. Researchers will then measure the arterial oxygen saturation in a finger, and compare it to the directly measured oxygen saturation in sampled radial arterial blood.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 20
- Inpatient at the University of Wisconsin University Hospital
- Has an internal jugular venous central line
- Has a radial arterial line
-
Currently receiving extracorporeal membrane oxygenation (ECMO)
-
Currently receiving continuous renal replacement therapy (CRRT/CVVH)
-
All usable lumens of the participant's jugular catheter are in use, and interruption of any medical or therapy through any lumen would, in the view of the primary care team, compromise the participant's care.
-
Jugular venous catheter is not functional or position is not confirmed by radiography
-
Arterial cannula is not functional
-
Known history of sickle cell anemia or other hemoglobinopathy
-
Therapy with any of the following medications:
- Nitroprusside
- Hydroxocobalamin
- Indocyanine green
- Norepinephrine
- Vasopressin
- Epinephrine
- Any other medication or therapy that, in the judgement of the study investigators, may affect the accuracy and precision of the noninvasive oximetry results
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Arm && Interventions
Group Intervention Description Critically ill adults Transreflectance oximetry probe Inpatient adults who require internal jugular venous central line and radial arterial line Critically ill adults Finger pulse oximetry probe Inpatient adults who require internal jugular venous central line and radial arterial line
- Primary Outcome Measures
Name Time Method Accuracy of digital pulse oximetry Through study completion, approximately 20 minutes Difference in the standard deviation of the arteriovenous saturation difference comparing noninvasive photoplethysmography to invasive blood sampling and oximetry
Accuracy of jugular pulse oximetry Through study completion, approximately 20 minutes Difference in the standard deviation of the arteriovenous saturation difference comparing noninvasive photoplethysmography to invasive blood sampling and oximetry
- Secondary Outcome Measures
Name Time Method