跳至主要内容
临床试验/NCT00678236
NCT00678236已完成不适用

A Migration and Bone Density Study Comparing Refobacin Bone Cement R vs. Refobacin Plus Bone Cement in the OptiPac Bone Cement Mixing System. A Prospective Randomized Study on Primary Total Knee Arthroplasty

University of Aarhus2 个研究点 分布在 1 个国家目标入组 54 人开始时间: 2008年6月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
54
试验地点
2
主要终点
Tibial implant migration evaluated by RSA

研究概览

简要总结

The goal of this scientific study is to determine whether there are differences in early migration and prosthesis-near bone density when a standard knee prosthesis is fixed with Refobacin Bone Cement R or with Refobacin Plus Bone Cement. Migration will be evaluated with RSA and bone density around the prosthesis with DEXA. The study will be successful if the prosthesis is fixed and remains in place throughout the entire period of the study, that is, that there is no increasing migration as measured by RSA. The cement type that ensures the largest number of solidly fixed prostheses during the two-year evaluation period will be "the best".

详细描述

Loosening of prosthetic components continues to play a large role in total knee alloplasty (TKA) and need for revision. Osteolysis is an important part of prosthesis loosening, but we still do not completely understand the mechanism. Research has shown that mechanical factors such as weak bone cement and poor contact between cement/bone or cement/implant interphase contribute to loosening of implants. Survival of cemented TKA components also depend on a careful balancing of soft tissues around the knee, repair of lower extremity dislocations, design of the prosthesis and the level of patients' activities. Sclerosis of the proximal tibia can present a problem with regard to getting the cement to penetrate into the bone. Poor operative technique, such as high volume or high pressure lavage of the prepared bone surface, can result in reduced penetration of cement into the spongiosa and early failure of the prosthesis, measured as progressive radiolucent lines (RLLs). En tourniquet counter acts bleeding at the implant site and provides for better penetration of cement into the trabeculae of the bone. If the bone surface at the implantation site is contaminated with blood before the cement is applied, the shear strength in the bone/cement interphase can be reduced by up to 50%.

In prosthesis used in this study includes a tibial plateau with a central stem with stabilizing wings, the bottom surface of which is recessed by about 1 mm, so that a pocket is formed surrounded by a lip that provides for an even thickness of the cement layer beneath the tibial plateau. This assures that the cement is pressed down into the spongiosa during fixation of the implant. This design doubles the penetration of the cement compared with prostheses without a depressed baseplate. The company behind this design has had a successful follow-up of this system for more than 15 years. A good cement/implant interphase lessens the risk of penetration of debris into the interphase and thus reduces the risk for the development of osteolysis and aseptic loosening of the implant.

Fixation of knee alloplasties is done in 70% of cases with use of cement. It is uncertain whether there is a difference in the long-term survival of knee prostheses with the two types of cement used in this project. Both types of cement in this study are used today in knee surgery with good, short-term clinical results. It is important to investigate new types of cement in order to assure future patients the best possible results after knee alloplasty and fewer re-operations.

The goal of this scientific study is to determine whether there are differences in early migration and prosthesis-near bone density when a standard knee prosthesis is fixed with Refobacin Bone Cement R or with Refobacin Plus Bone Cement. Migration will be evaluated with RSA and bone density around the prosthesis with DEXA. The study will be successful if the prosthesis is fixed and remains in place throughout the entire period of the study, that is, that there is no increasing migration as measured by RSA. The cement type that ensures the largest number of solidly fixed prostheses during the two-year evaluation period will be "the best".

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Diagnostic
盲法
Single (Participant)

入排标准

年龄范围
70 Years 至 —(Older Adult)
性别
All
接受健康志愿者

入选标准

  • primary or secondary knee osteoarthritis
  • sufficient bone quality for total knee arthroplasty
  • age above 70 years
  • no upper age limit if the patient is capable
  • informed and written consent
  • patient can only enter the project with one knee

排除标准

  • neuromuscular or vascular disease in the affected leg
  • preoperatively not found suitable for a knee arthroplasty
  • patients with osteoporosis based on former diagnosis or preoperative DEXA-scan
  • fracture sequelae or previous PTO or previous extensive knee surgery
  • patients with need of a stem-elongation
  • patients who cannot refrain from taking NSAID post-operatively
  • continuous medical treatment with vitamin K antagonists (Warfarin) which is known to reduce the bon emineral density by a factor of 5
  • patients with metabolic bone disease
  • patients with rheumatoid arthritis
  • postmenopausal women in estrogenic hormone substitution
  • patients with a continuous need of systemic cortisone treatment
  • non-Danish citizenship
  • patients who do not comprehend the Danish language (read and speak)
  • senile dementia
  • alcoholism - defined as men drinking more than 21 units a week and women drinking more than 14 units a week
  • drug abuse
  • major psychiatric disease
  • metastatic cancer disease and treatment with radiation therapy or chemotherapy
  • severe systemic disease (e.g. hemi paresis and Parkinson disease)
  • systemic hip and spine disease
  • employee at the orthopaedic department, Aarhus University Hospital
  • ongoing case regarding industrial injury insurance of the knee
  • patients with poor dental status (risk of infection)

结局指标

主要结局

Tibial implant migration evaluated by RSA

时间窗: 2013

次要结局

  • Comparison of Refobacin Bone Cement R vs. Refobacin Plus Bone Cement(2013)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验