Comparison of Transpalpebral Easyton Tonometer with Goldmann Appalanation Tonometer in Persons with Glaucoma
试验速览
- 阶段
- 不适用
- 状态
- 暂停
- 发起方
- AUROLAB
- 入组人数
- 260
- 试验地点
- 1
- 主要终点
- Evidence of the accuracy and agreement of IOP measured using EASYTON transpalpebral tonometry in comparsion with the GAT and also the possibility of finding an alternative to GAT especially in screening patients for glaucoma in the community and general ophthalmology clinics
研究概览
简要总结
| Glaucoma is the second leading cause of blindness worldwide. Asians represent 47% of those with glaucoma and 87% of those with angle closure glaucoma. To the best of our knowledge, till date, elevated intraocular pressure (IOP) is the only modifiable risk factor. Also, lowering the IOP is the only proven method of halting disease progression. Hence, accurate tonometry is indispensable in the diagnosis and management of glaucoma. Goldmann applanation tonometer (GAT) considered as the reference standard tonometry for measuring IOP, has its own limitations. Despite its accuracy, there are some known disadvantages of GAT. The IOP readings are affected by central corneal thickness (CCT) and corneal pathologies, the need for use of local anesthesia and the risk of transmissible infections as the prism needs to be in contact with cornea. Therefore, exploring alternative methods have always been a point of interest. This propelled us to assess the validity of the Easyton tonometer, which is a new version of transpalpebral tonometry. Therefore, exploring alternative methods have always been a point of interest. This propelled us to assess the validity of the Easyton tonometer, which is a new version of transpalpebral tonometry compared with GAT. The possible outcome of the study will to find an effective alternative to GAT, especially in screening patients for glaucoma in the community and general ophthalmology clinics. |
研究设计
- 研究类型
- Observational
入排标准
- 年龄范围
- 18.00 Year(s) 至 80.00 Year(s)(—)
- 性别
- All
入选标准
- •Patients diagnosed with Primary Open Angle Glaucoma, Primary Angle Closure Disease, Pseudo exfoliation Glaucoma, Pigmentary Glaucoma, Normal Tension Glaucoma, Juvenile Glaucoma, Ocular Hypertension and Glaucoma suspects.
排除标准
- •Evident scleral and/or conjunctival pathology 2) Presence of transmissible infections/conjunctivitis/keratitis/blepharitis 3) Presence of lid abnormalities such as chalazia, entropion, ectropion, exposure keratitis 4) Presence of corneal diseases precluding GAT, corneal edema, bullous keratopathy and corneal scars 5) Debilitated patients and those with difficulty in neck posture maintenance, cervical spondylitis 6) Inflammatory eye diseases uveitis, significant diabetic retinopathy.
结局指标
主要结局
Evidence of the accuracy and agreement of IOP measured using EASYTON transpalpebral tonometry in comparsion with the GAT and also the possibility of finding an alternative to GAT especially in screening patients for glaucoma in the community and general ophthalmology clinics
时间窗: 3 months
次要结局
- Submission of the findings in a peer reviewed journal(12 months)
研究者
研究点 (1)
Loading locations...
相似试验
已完成
4 期
A Trial to study the effects of two drugs travoprost & brimonidine/timolol combination in patients with kanchbind (high pressure in eyes).CTRI/2011/11/00210570
已完成
不适用
Assessment of Home Tonometry in GlaucomaGlaucomaIntraocular PressureNCT03057301NHS Lothian100
Unknown
不适用
Asia Glaucoma RegistryPOAGNCT05278299The University of Hong Kong20
尚未招募
2/3 期
COMPARISON OF GLAUCOMA SURGERY(TRABECULECTOMY) IN OPEN ANGLE GLAUCOMA AND CLOSED ANGLE GLAUCOMACTRI/2020/05/025095Maulana Azad Medical College60
进行中(未招募)
4 期
A Study to Evaluate Adverse Events and Change in Disease Activity With the XEN45 Glaucoma Treatment System Implantation In Adult Participants With Open-Angle Glaucoma in ChinaOpen-angle GlaucomaOAGNCT05821855AbbVie120