跳至主要内容
临床试验/NCT00584181
NCT00584181已完成不适用

High Resolution Computed Tomographic Evaluation of Airway Distensibility in Lung Transplant Recipients: A Pilot Study

The University of Texas Medical Branch, Galveston1 个研究点 分布在 1 个国家目标入组 10 人开始时间: 2007年8月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
10
试验地点
1
主要终点
Spirometry changes

研究概览

简要总结

Lung and heart-lung recipients at the University of Texas Medical Branch who have participated in the "Assessment of Cough Reflex in Lung Transplant Recipients" study who meet the specific study inclusion/exclusion criteria will have one study visit where they will undergo lung volume measurements, followed by high resolution CT scan of the lungs within 2 hours. After the initial CT scan, patients will be given a standard dose of Atrovent, followed thirty minutes later by repeat lung volume measurements and CT scan.

详细描述

Chest CT imaging will be obtained in the radiology department at UTMB. After the initial screening visit, subjects will visit the pulmonary function laboratory where they will undergo spirometry and measurement of lung volumes by whole body plethysmography. Within two hours of pulmonary function testing, subjects will undergo an initial HRCT scan. After the initial HRCT, subjects will inhale a standard dose of ipratropium bromide (0.5 mg) using a hand held nebulizer. Thirty minutes after ipratropium bromide administration, spirometry will be measured followed by a second HRCT scan.

Spirometry measurements will be performed in triplicate with the subjects in a seated position using a portable Koko spirometer (PDS, Louisville, CO). After the spirometry measurements, lung volumes will be measured in a body plethysmograph (MedGraphics, St. Paul, MN) with the subjects in a seated position with a nose clip. Subjects will be instructed to pant against the closed shutter at a frequency of 1-3 Hz. Lung volume measurements will be obtained prior to inital chest CT. Subjects will undergo high resolution computed tomography (HRCT) scanning within 30 minutes of initial lung volume measurements.

After the initial HRCT of the chest, subjects will inhale a dose of nebulized ipratropium bromide (0.5 mg) by standard nebulizer after which spirometry and lung volume measurements will be repeated in the pulmonary function laboratory. Spirometry and lung volume measurements will be performed in the same manner. Lung volume measurements will be obtained to account for changes in lung volumes after bronchodilator administration. Changes in lung volumes will be used to account for any changes noted on HRCT scans.

HRCT scanning will begin 6 cm above the top of the dome of the diaphragm, at TLC and moved caudally. Images will be reconstructed with the use of a high-spatial frequency (resolution) algorithm that enhanced edge detection, at a window level of -450 Hounsfield units and a window width of 1,350 Hounsfield units. We will consider the airway diameters after maximum bronchodilation with ipratropium to be a function principally of the structural characteristics of airways. The TLC measurements after ipratropium will be the best reflection of intrinsic structure. CT airway measurement analysis will be performed by VIDA Diagnostics. We have entered into a collaboration with VIDA Diagnostics that will allow accurate and reliable CT airway measurements. Subject's CT images obtained at UTMB will be deidentified and electronically transmitted to a research collaborator at VIDA Diagnostics located in Coralville, IA. The CT images will have a code assigned, known only to the PI. Using a proprietary software platform, airway measurements will be performed and the data electronically transmitted to the PI at UTMB.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • lung transplant recipients >18 years of age
  • at least 12 months or greater from time of transplantation

排除标准

  • hemodynamic instability
  • hypoxemia
  • pneumonia
  • moderate or large pleural effusion
  • clinical evidence of acute rejection

结局指标

主要结局

Spirometry changes

时间窗: Two hours (before and after inhalation of ipratropium)

Assessment of changes in spirometry following inhalation of nebulized ipratropium

次要结局

  • Lung volumes(Two hours (before and after inhalation of ipratropium))

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验

High-resolution Computed Tomography (HRCT)... | 临床试验